Summary of Contents for Toshiba MMU-UP0091H-E

  • Page 1 AIR CONDITIONER (MULTI TYPE) Owner’s Manual R410A For commercial use Indoor Unit Model name: <4-way Cassette type> MMU-UP0091H-E MMU-UP0271H-E MMU-UP0121H-E MMU-UP0301H-E MMU-UP0151H-E MMU-UP0361H-E MMU-UP0181H-E MMU-UP0481H-E MMU-UP0241H-E MMU-UP0561H-E English...
  • Page 2: Table Of Contents

    4 Operation ............8 work on the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been...
  • Page 3 ■ Warning indications on the air conditioner unit These safety cautions describe important matters concerning safety to prevent injury to users or other people and damages to property. Please read through this manual after understanding the contents below (meanings of indications), and be sure to follow the description.
  • Page 4: Precautions For Safety

    – 3 – Precautions for safety Installation • Only a Qualified installer (*1) or Qualified service person (*1) is The manufacturer shall not assume any liability for the damage caused allowed to carry out the electrical work of the air conditioner. Under by not observing the description of this manual.
  • Page 5 • Use of a stand more than 50 cm high to clean the filter of the indoor Repairs unit or to carry out other such jobs constitutes working at heights. Due • When you have noticed that some kind of trouble (such as when a to the danger of falling off the stand and injuring yourself while check display has appeared, there is a smell of burning, abnormal working at heights, this kind of work should not be done by unqualified...
  • Page 6 – 5 – CAUTION Installation • Certainly lay the drain hose for perfect draining. Improper drainage may cause flooding in the house and getting furniture wet. • Connect the air conditioner to an exclusive power supply of the rated voltage, otherwise the unit may break down or cause a fire. •...
  • Page 7: Part Names

    ■ Part names Information on the transportation, handling and storage of the carton ■ Indoor unit Examples of indication on the carton Hook Symbol Description Symbol Description Hook to open and close the air intake grille. Keep dry Do not drop Air discharge, discharge louvre Change the direction of the wind blowing out when warming or cooling the room.
  • Page 8: Part Names And Functions Of The Remote Controller

    – 7 – ■ Part names and functions of the remote Indicators All icons on the display are shown for this explanation. Operations are not accepted when “SETTING” is flashing. controller Remote controller model name: RBC-ASCU11- LCD back-light lights for 15 seconds during remote controller operation. All indicators are displayed in the display example below.
  • Page 9: Operation

    Operation OFF timer operation OFF timer: The indoor unit stops when the set time is reached. When you use the air conditioner for the first time or change the settings, follow the procedures below. From next time, pushing the ON/OFF button starts running of the air conditioner with the chosen settings. ■...
  • Page 10: Louvre Direction

    – 9 – Louvre direction ▼When cooling ▼When heating Point the louvre horizontally. Point the louvre downward. ▼For cooling NOTE The louvre can be adjusted to four steps. To improve the cooling / heating performance, change Point the louvre horizontally. If pointing downward, dew the louvre angle for each operation.
  • Page 11: Notes On Operations And Performance

    ■ Notes on operations and performance Cooling / Heating operations Each unit can be controlled individually. However, indoor units connected to the same outdoor unit cannot perform ■ ■ cooling and heating simultaneously. Check before operation Protective device When you attempt simultaneous operation, indoor units performing cooling are stopped, and the running (High pressure switch) preparation indicator is displayed on the remote controller.
  • Page 12: Tips For Energy Saving And Comfortable Performance

    – 11 – Tips for energy saving and comfortable Maintenance performance WARNING To save energy and perform comfortable cooling and heating. For daily maintenance including Air Filter cleaning, make sure to ask the Qualified service person particularly. Clean the air filter often Do not cool / heat too much •...
  • Page 13: When The Following Symptoms Are Found

    ■ ■ When the following symptoms are found Cleaning the indoor unit and Before the cooling season remote controller Ask a Qualified service person to clean the drain Check the points described below before asking repair servicing. pan. • Ask Qualified service person to clean the indoor Symptom Cause units for the models listed in the warning on the top...
  • Page 14: Specifications

    If a problem occurs with the air Weight (kg) Model Main unit (Ceiling panel) conditioner, the OFF timer indicator Cooling Heating alternately shows the check code and MMU-UP0091H-E 18 (5) the indoor Unit No. in which the MMU-UP0121H-E 18 (5) problem occurred. MMU-UP0151H-E 25 (5)
  • Page 15: Mmu-Up0091H-E

    Declaration of Conformity Manufacturer: TOSHIBA CARRIER CORPORATION 336 Tadehara, Fuji-shi, Shizuoka-ken 416-8521 JAPAN TCF holder: TOSHIBA CARRIER EUROPE S.A.S Route de Thil 01120 Montluel FRANCE Hereby declares that the machinery described below: Generic Denomination: Air Conditioner Model / type: MMU-UP0091H-E, MMU-UP0121H-E, MMU-UP0151H-E,...
  • Page 16 EH99967801 (DH91307901)