5. LED Indication
Function
LED status
LED turns ON 1 time
Working fine
per 2s
Modify the
address of
LED turns on
motor
Testing for
LED turns OFF 1
installation
time per 2s
Easy
LED Turns OFF 2
programming
times per 2s
Note: the above operations are carried out in normal work.
6. Software Configuration
6.1 Workflow
a)
When power on, test the distance of the curtain by itself, then, short press PROG
button and control the curtain, make sure the curtain is working properly.
b)
Change the address of curtain by HDL-BUS pro or HDL Easy Engineering Editor
software.
c)
Confirm the motor's running mode, forward or reverse.
d)
Set the work mode: long drag, short drag, drag no action.
e)
Set the reserved distance. (Don't change after setting.)
f)
Set the panel's target and control the curtain.
Note: the Step c), d), e) are set by HDL Easy Engineering Editor software.
6.2 Modify address of motor
Long press the button 3s, the LED will turn ON, then you can modify the address by HDL
Easy Engineering Editor software. Press the button 3s again or has no action after 2min, it
Curtain Motors – User Manual
HDL-MWM70B.12/MWM70S.12
enter into the status
--
long press the button 3s
long press the button 5s
long press the button 10s
User Manual
exit the status
--
long press the button 3s
/ no operation 2minutes
long press the button 5s
/ no operation 20minutes
long press the button
10s / no operation
20minutes
10