12.5.1 VERSIONS WITH INTERNAL CAPILLARY TUBE THERMOSTAT
Remove the connection box cover. The electrical wiring
•
diagram shown is contained in the cover.
Insert the mains cable (min. 3 x 1.5 mm
•
cable gland and connect to the appropriate terminals.
•
Insert the signal cable (low temperature alarm) through
the cable entry and connect to the appropriate terminals
(contact position T
•
Screw the cover back in place again.
The use of temperature-resistant cable is recommended!
Note
12.5.2 VERSION WITH EXTERNAL THERMOSTAT
•
Remove the cover of the connection box. The
electrical wiring diagram shown is contained in
the cover.
•
Insert the mains cable (min. 3 x 1.5 mm
through the cable gland and connect to the
appropriate terminals.
•
Insert the temperature sensor cable through the
cable entry and connect to the appropriate
terminals.
•
Screw the cover back in place again.
Use appropriate compensating cables for thermocouples!
Note