8 Settings
"Installation settings" menu area

8.4.8 EPO (External Shutdown)

Overview
This function allows you to define the external shutdown (EPO)
relay contacts as being normally closed or normally open con-
tacts.
Setting options
Parameter
EPO
Menu item path
Main Menu > Install Settings > EPO
Setting External Shutdown (EPO)
1 0 . N o v 2 0 1 9 1 5 : 3 2
S t a t u s :
O n G r i d
P o w e r :
E - T o d a y :
I n v e r t e r I n f o .
G e n e r a l S e t t i n g s
I n s t a l l S e t t i n g s
A c t i v e / R e a c t i v e P w r
F R T
W a r n i n g :
A d j . w o u l d a f f e c t
e n e r g y p r o d u c t i o n .
P a s s w o r d
0 * * *
G r i d S e t t i n g s
D C I n j e c t i o n
D r y C o n t .
D i s a b l e d
R C M U :
E P O :
N o r m a l C l o s e
98
Description
Defines how the relay functions for the external
shutdown (EPO).
1.
When the default information is displayed, press any button to open the main menu.
Otherwise, press the
0 W
0 k W h
2.
Use the
the
button.
ENT
3.
This function is protected with password 5555.
Use the
Press the
ENT
4.
Use the buttons
→ If the shape of the arrow changes
O N
The currently set value is displayed after the entry.
5.
Use the
Setting range
nrm. open | nrm. closed
button repeatedly until the main menu is displayed.
ESC
and
buttons to select the Install Settings entry and then press
and
buttons to set the individual numerals.
button to confirm a numeral.
and
to select the entry EPO and press the
and
buttons to configure the value and then press the
Installation and Operation Manual for Power Inverter RPI M6A M8A M10A EU V4 EN 2020-07-13
, the value can be changed.
button.
ENT
button.
ENT