Description - Cantel Medical MEDIVATORS renatron II 100 Series Instruction Manual

Dialyzer reprocessing system
Table of Contents

Advertisement

ELECTRIC SHOCK HAZARD: ONLY QUALIFIED PERSONNEL SHOULD REMOVE
TOP COVER.
CAUTION – DO NOT OPERATE THE RENATRON
SPECIFICALLY INDICATED IN THIS MANUAL.
CAUTION – ALL PERSONNEL USING THIS DEVICE SHOULD BE FAMILIAR WITH THE INFORMATION
CONTAINED IN THIS MANUAL.
CAUTION – IT IS THE RESPONSIBILITY OF THE PRESCRIBING PHYSICIAN TO ENSURE THAT THE
OPERATORS OF THIS DEVICE ARE PROPERLY TRAINED AND TECHNICALLY COMPETENT.
CAUTION – DO NOT REMOVE ANY WARNINGS, CAUTIONS, OR DESCRIPTIVE LABELING FROM THIS
MACHINE OR THE POWER CORD SUPPLIED WITH THIS MACHINE.
CAUTION – ALL PLUMBING (HOSES AND LINES) ARE CUT TO LENGTH AND CALIBRATED AT THE
FACTORY AND SHOULD NOT BE MODIFIED FROM THE ORIGINAL LENGTHS OR SIZES. ONLY FACTORY
AUTHORIZED SERVICE PERSONNEL SHOULD REPAIR OR REPLACE THESE ITEMS.
RENALIN
100 COLD STERILANT IS USED IN CONJUNCTION WITH THIS DEVICE.
®
RENALIN 100 COLD STERILANT IS CORROSIVE AND CAN CAUSE EYE DAMAGE
AND SKIN IRRITATION. WEAR EYE PROTECTION, GLOVES AND PROTECTIVE
CLOTHING WHEN HANDLING THIS SOLUTION AND DURING THE OPERATION
OF THE RENATRON II 100 MACHINE.
CAUTION – THE OPERATOR SHOULD BE FAMILIAR WITH THE SAFE HANDLING TECHNIQUES FOR
THE MACHINE AND THE RENALIN 100 COLD STERILANT AND WITH THE RECOMMENDED FIRST AID
PROCEDURES IN CASE OF CONTACT WITH OR EXPOSURE TO RENALIN 100 COLD STERILANT.
DO NOT ALLOW RENALIN 100 COLD STERILANT TO MIX WITH ALKALINE
SUBSTANCES SUCH AS BLEACH (SODIUM HYPOCHLORITE)
CAUTION — THIS MACHINE IS INTENDED EXCLUSIVELY FOR THE SOLE PURPOSE OF IN-VITRO
CLEANING OF, TESTING OF DELIVERY OF RENALIN 100 SOLUTION TO AND RECORD KEEPING FOR
PREVIOUSLY USED HOLLOW FIBER DIALYZERS. ANY SUBSEQUENT, CLINICAL APPLICATION OR USE
OF A HOLLOW FIBER DIALYZER THAT HAS BEEN REPROCESSED BY THIS IS THE SOLE RESPONSIBILITY
OF THE PRESCRIBING PHYSICIAN.
A. Components: the RENATRON II 100 Series System consists of:
1. A RENATRON II 100 Series station (1 to 12 can be used with the system):
a. The solid-state electronics control section
b. The RS-232 serial port, for data communications
c. The hydraulic section
d. The dialysate inlet and outlet port connection and the arterial and venous port connection lines
e. The RENALIN 100 uptake hose
f.
The drain line hose
2. RENALOG
RM Data Management System:
®
a. Desktop computer
b. RENALOG RM Dialyzer Reprocessing Data Management software package
c. Color monitor
d. Label printer
e. Report printer
f.
Interface module
WARNING
II 100 SERIES MACHINE WITH THE COVER OFF UNLESS
®
WARNING
WARNING
-5-

Description

Instruction Manual