1. Loosen the coupling nut (1) (not com-
pletely).
2. Insert the device connection (12c) of
the compressed air hose (12) into the
retainer.
3. Retighten the coupling nut (1).

Operation

Infl ation
Cordless air pump
1. Remove the valve cap on the
infl atable item.
2. Place the desired valve adapter
(23) on the air exhaust opening
(18) of the cordless air pump.
3. Insert the valve adapter (23) into
the valve on the infl atable item.
4. Turn the device on (On/off
switch (20) to position "I").
5. Switch the device off (On/off
switch (20) to position "0") when
the desired fi lling volume has
been reached.
6. Remove the valve adapter (23).
7. Put the valve cap of the infl atab-
le item back on.
Cordless compressor
1. Remove the valve cap on the
infl atable item (if applicable).
2. Mount the compressed air hose
(12) (if applicable).
3. Open the locking lever (12a) (if
applicable).
4. Place the desired valve adapter/
ball needle (13/14/15/16) on
the valve connection (12b) of the
compressed air hose (12).
5. Close the locking lever (12a)
again (press towards the com-
pressed air hose).
6. Set the desired pressure on the
display (4) (see "Changing the
pressure setting").
7. Insert the ball needle/valve ad-
apter (13/14/15/16) into the
valve on the infl atable item.
8. Turn the device on (see "Swit-
ching on/off").
9. Press the On/off switch (10).
The LED work light (11) lights
up. When the preconfi gured
pressure is reached, the device
switches off automatically.
10. Remove the valve adapter/ball
needle (13/14/15/16).
11. Put the valve cap of the infl atab-
le item back on (if applicable).
Defl ation
(only the cordless air pump)
1. Place the appropriate valve adapter
(23) on the air inlet opening (17) of the
cordless air pump.
2. Remove the valve cap of the infl atable
item and insert the valve adapter (23)
into the valve on the infl atable item.
3. Turn the device on (On/off switch (20)
to position "I").
4. Once the infl atable item is entirely
defl ated, switch the device off (On/off
switch (20) to position "0").
5. Remove the valve adapter (23).
6. Put the valve cap of the infl atable item
back on.