SPECIFICATIONS
Find Quality Products Online at:
Function
Range
AC/DC Current
400.0A
(Clamp on)
2000A
AC Voltage
4.000V
True RMS
40.00V
400.0V
1000V
DC Voltage
400.0mV
4.000V
40.00V
400.0V
1000V
Resistance
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
AC/DC Current
400.0µA
(Direct Input)
4000µA
40.00mA
400.0mA
Frequency
5Hz
50Hz
500Hz
5kHz
50kHz
100kHz
Capacitance
50nF
500nF
5µF
50µF
Duty Cycle
1 to 99%
Continuity
Audible tone; <10 ohms approximately
Open circuit voltage; 0.5V approximately
GlobalTestSupply
www.
Resolution
Accuracy
Remarks
0.1A
±(2.0% + 5d)
45Hz to 1KHz
1A
±(2.0% + 8d)
1mV
±(1.2% + 5d)
45Hz to 1KHz
Input Impedance:
10mV
10Mohms
0.1V
1V
0.1mV
±(0.5% + 2d)
Input Impedance:
10Mohms
1mV
±(1.0% + 2d)
10mV
0.1V
1V
±(1.0% + 5d)
0.1Ω
1Ω
10Ω
100Ω
±(2.0% + 2d)
1kΩ
±(3.5% + 5d)
10kΩ
0.1µA
±(1.2% + 5d)
45Hz to 1KHz
1µA
0.01mA
0.1mA
0.001Hz
±(1% + 5d)
0.01Hz
0.1Hz
1Hz
10Hz
100Hz
10pF
±(3% + 5d)
Accuracy stated
after a relative "REL"
100pF
zero performed
0.001µF
0.01µF
0.1%
±(1% + 5d)
8
.com
380926 -EN-V7.1-3/12
sales@GlobalTestSupply.com
Need help?
Do you have a question about the Extech 380926 and is the answer not in the manual?