Electrical Information; Ventilation Requirements - Winston Industries CVap Single Dial Series Owner's Manual

Holding cabinet
Table of Contents

Advertisement

holding cabinet
electrical
The appliance is shipped from the factory
with a 7' (213cm) (minimum) power cord and
plug. Refer to the table below to determine
the correct electrical outlet. It may be
Model
Volts
Hertz
HAD022
120
60
230
50
INTERNATIONAL

ventilation requirements

.
Ventilation clearances
the appliance will need sufficient space for air
circulation. Allow at least 2" (51mm)
clearance on all sides, particularly around
ventilation holes. Care should be taken to
prevent placing the appliance close to
anything combustible. It must be installed with
its supplied legs, feet, or casters. Counter top
appliances supplied without legs or casters
may be placed directly upon a counter top of
non-combustible material. In this situation, the
appliance may have to be sealed to the
counter top with a food-grade silicone sealant
(check local health codes). Half size
appliances may be stacked upon each other
using only a Winston supplied stacking kit
and following the instructions enclosed with
the kit. Your warranty may be void if you do
not adhere to these ventilation requirements.
6
PH
Amps
Watts
Amp
1
15.3
1840
1
8.0
1840
- To operate properly,
Model HAD022
www.winstonind.com • 800.234.5286
necessary to hire a licensed electrician to
install the correct outlet or wiring. Winston
does not recommend wiring the unit direct.
Below is electrical information for various
models of Winston's CVap
Circuit
Type
US 20 /CAN 30
N/A
High Temperature and Grease Hazard
Can cause damage to appliance.
Avoid placing appliance near high heat or in grease
laden atmosphere.
Do not place appliance in an area where
ambient temperatures (air temperatures
around the appliance) exceed 100˚F (38˚C). A
heat shield may be required to prevent
excessive heat exposure and grease laden
vapors from affecting the appliance if
adjacent to heat, vapor, or grease generating
devices (such as grills, steamers, ovens,
etc.). Excess heat and grease inside the
appliance cavities may cause electrical
components to fail.
Vent hood
- Generally this appliance does
not need to be installed under a mechanical
ventilation system (vent hood). Check local
health and fire codes for requirements
specific to your location.
holding cabinets.
®
Plug
US 5-20P/CAN 5-30P
N/A