Main Switch - Atlas Copco GA 7 VSD+ Instruction Book

Oil-injected rotary screw compressors
Table of Contents

Advertisement

Instruction book
Temperature input
Water inlet temperature of energy recovery
Water inlet temperature of energy recovery
Energy recovery water outlet temperature
Energy recovery water outlet temperature
To modify a setting, consult the relevant section in the description of the Elektronikon controller.
Recoverable energy
The recoverable energy can be calculated from:
RECOVERED ENERGY (kW) = 4.2 x water flow (l/s) x water temperature rise (˚C)
In the tables below, typical examples are given.
Data for low temperature rise/high water flow systems
Parameter
Recoverable energy
Recoverable energy
Temperature at inlet
Temperature at inlet
Temperature at outlet
Temperature at inlet
Data for high temperature rise/low water flow systems
Parameter
Recoverable energy
Recoverable energy
Temperature at inlet
Temperature at inlet
Temperature at outlet
Temperature at inlet
5.2

Main switch

A build-in main switch can be ordered from factory
2920 7109 23
Unit
GA7
+
VSD
kW
6.2
hp
8.4
˚C
50
˚F
122
˚C
60
˚F
140
Unit
GA7
+
VSD
kW
6.2
hp
8.4
˚C
20
˚F
68
˚C
60
˚F
140
Minimum
setting
˚C
0
˚F
32
˚C
0
˚F
32
GA11
+
VSD
9.7
13.2
50
122
60
140
GA11
+
VSD
9.7
13.2
20
68
60
140
Nominal
Maximum
setting
setting
50
99
122
210
Depends on
99
application
Depends on
210
application
GA15
+
VSD
13.2
18.0
50
122
60
140
GA15
+
VSD
13.2
18.0
20
68
60
140
95