Atlas Copco GA 7 VSD+ Instruction Book page 101

Oil-injected rotary screw compressors
Table of Contents

Advertisement

Instruction book
Step
Action
10
Open the air outlet valve.
Start and run the compressor for a few minutes. Check that the compressor operates normally.
Starting
Step
Action
1
Open the air outlet valve.
2
Switch on the voltage. Check that voltage on LED (6) lights up.
3
Press start button (1) on the control panel. The compressor starts running and the automatic
operation LED (8) lights up.
During operation
Keep the panels closed during operation.
When the motors are stopped and LED (8) (automatic operation) is alight, the motors may start
automatically.
When the automatic operation LED (8) is lit, the regulator is automatically controlling the
compressor, i.e. loading, unloading, stopping of the motors and restarting!
Regularly check the oil level:
2920 7109 23
Control panel Elektronikon® Graphic
99

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga 11 vsd+Ga 15 vsd+

Table of Contents