Toro Multi Pro 5800 Operator's Manual page 7

Turf sprayer with excelarate spray system
Hide thumbs Also See for Multi Pro 5800:
Table of Contents

Advertisement

Setting the Low Limit Volume Value
1.
Press button 1 or 2 to navigate to the
volume option
(Figure
2.
Press button 4 to select the
entry
(Figure
14).
3.
Press button 3 or 4 to raise or lower the threshold
volume at which the limit indicator displays in
the InfoCenter
(Figure
4.
Press button 5 to save the setting, exit the
screen, and return to the
Setting the Preset Agitation Value (Application
Rate Mode Only)
Note:
The preset agitation setting is used to set the
sprayer pump speed when the sprayer is operated
in the Application Rate Mode with all sprayer section
shut off. The preset agitation setting controls the
percentage of sprayer pump speed. The default
preset agitation setting is 40%.
1.
Identify the target sprayer pressure that you are
planning to spray—for example: 2.76 bar (40
psi). Record the pressure displayed on the dash
mounted sprayer-pressure gauge below.
Sprayer
pressure:
2.
Calculate the initial agitation preset pressure
using the formula below:
Sprayer operation pressure x 1.5 to 2.0 = initial agitation preset
pressure
Example: target sprayer pressure 2.76 bar (40 psi)
x 1.5 = initial agitation preset pressure 4.1 (60 psi)
Example: target sprayer pressure 2.76 bar (40 psi) x 2.0 = initial
agitation preset pressure 5.5 bar (80 psi)
Record your
calculation here:
3.
With the master section switch in the O
position and the engine throttle set to the engine
LOW LIMIT
14).
Figure 14
volume
LOW LIMIT
14).
screen.
SETTINGS
speed you intend to run the machine, adjust the
preset agitation value until the sprayer system
pressure is between 1.5 to 2.0 times the target
sprayer pressure that you identified in step 1.
For example, if you are spraying at 2.76 bar (40
psi), initially set Preset Agitation to achieve a
system pressure of 4.1 to 5.5 bar (60 to 80 psi).
Note:
foaming, lower the preset agitation value as
necessary to reduce system pressure when tank
agitation is running.
4.
Press button 1 or 2 to navigate to the
option
g191829
TANK
5.
Press button 4 to select the A
(Figure
6.
While watching the dash mounted
sprayer-pressure gauge, press button 3
or 4 to raise or lower the preset value until the
sprayer pressure is at the initial agitation preset
pressure that you calculated in step
15).
Note:
system pressure when adjusting the preset
agitation value.
Note:
higher if agitation does not cause the chemical
in the tank to foam. You may need to lower the
agitation value if agitation causes the chemical
in the tank to foam.
7.
Press button 5 to save the setting, exit the T
screen, and return to the S
FF
7
If the chemicals in the sprayer tank are
(Figure
15).
Figure 15
15).
Do not exceed 586 kPa (85 psi) sprayer
You may set the preset agitation value
ETTINGS
AGITATION
g191830
entry
GITATION
2 (Figure
ANK
screen.