Installation

Installation diagram
Unit: mm
Hanging plate installation
Drill piping hole
AMS-SVX03A-EN
Ceiling
>150
Ground
Only air conditioning unit installed by professionals in accordance with this manual can
ensure good status.
Find the level position with hanging line. When adjust the board, the left side should be
lower since the drainage pipe is at the same side.
Fix the hanging plate on the wall with screws.
Pull the hanging plate to make sure it is fi xed after installation completed. Properly installed
hanging plate can withstand 60kg and all fi xed screws are stressed uniformly.
Outlet pipe wall hole diameter: 50mm for MW(C)W509/512, and 65mm. for MW(C)W518.
Drill a outward-dipping hole ( 50 or
Install wall pipe to prevent piping and cable through the wall from damaging.
>150
65) after determining the piping hole position.
Ceiling
>3000
Ground
Outlet pipe wall hole Ø
Wall