3.3.2

Module Shutdown

The module can be shut down by the following controls:
Shutdown Control Action
Software
Sending AT+CFUN=0 command
Hardware
Pull down FCPO# pin
The module can be shut down by sending AT+CFUN=0 command. When the module receives the software
shutdown command, the module will start the finalization process (the reverse process of initialization),
and it will be completed after t
response, the max t
sd
some other parameters from memory, and then clear the memory and shut down PMU. The control timing
is shown in Figure 3-6:
+3.3V
FCPO#
RESET#
PERST#
Module State
Index Min.
Recommended Max.
t
16ms
20ms
off1
t
2ms
10ms
off2
t
10ms
100ms
pd
Note:
When USB is used as data transfer interface, follow timing above in PERST# connecting with
host, otherwise don't control PERST# in PERST# floating condition.
Reproduction forbidden without Fibocom Wireless Inc. written authorization - All Rights Reserved.
FIBOCOM L850-GL Series Hardware Guide
time (t
is the time which AP receive OK of "AT+CFUN=0", if there is no
sd
sd
is 5s). In the finalization process, the module will save the network, SIM card and
AT+CFUN=0
Activation
Figure 3-6 Shutdown timing control
-
-
-
Condition
Normal shutdown(recommend)
Only used when a hardware exception
occurs and the software control cannot be
used.
t
sd
Finalization
Comments
RESET# should be asserted after PERST#
FCPO# should be asserted after RESET#
+3.3V power supply goes down time. If power supply is
always on, it can be ignored
t
pd
t
off2
t
off1