Entering the
Softkey Interface
From the "pmon"
User Interface
2-8 Getting Started
If you have installed your emulator and Softkey Interface software as
directed in the HP 64700 Series Emulators Softkey Interface
Installation Notice, you are ready to enter the interface. The Softkey
Interface can be entered through the pmon User Interface Software or
from the HP-UX shell.
If /usr/hp64000/bin is specified in your PATH environment variable,
you can enter the pmon User Interface with the following command.
$ pmon <RETURN>
If you have not already created a measurement system for the 7700
Series emulator, you can do so with the following commands. First
you must initialize the measurement system with the following
command.
MEAS_SYS msinit <RETURN>
After the measurement system has been initialized, enter the
configuration interface with the following command.
msconfig <RETURN>
To define a measurement system for the 7700 Series emulator, enter:
make_sys emm77 <RETURN>
Now, to add the emulator to the measurement system, enter:
add <module_number> naming_it m77 <RETURN>
Enter the following command to exit the measurement system
configuration interface.
end <RETURN>
If the measurement system and emulation module are named "emm77"
and "m77" as shown above, you can enter the emulation system with
the following command:
emm77 default m77 <RETURN>
If this command is successful, you will see a display similar to Figure
2-4. The status message shows that the default configuration file has
been loaded. If the command is not successful, you will be given an
error message and returned to the pmon User Interface. Error
messages are described in the Softkey Interface Reference manual.