Trace List
Label:
Address
Base:
symbols
+015
:cmd_rds:+000002
+016
:cmd_rds:+000002
+017
:cmd_rds:+000003
+018
:cmd_rds:+000004
+019
:cmd_rds:+000004
+020
:cmd_rds:+000005
+021
:cmd_rds:+000006
+022
:cmd_rds:+000006
+023
:cmd_rds:+000007
+024
:cmd_rds:+000008
+025
:cmd_rds:+000008
+026
:cmd_rds:+000009
+027
:cmd_rds:+00000A
+028
:cmd_rds:+00000A
+029
:cmd_rds:+00000B
STATUS:
M37700--Running user program
display trace
run
trace
Displaying Trace with
Time Count Absolute
2-28 Getting Started
Offset=0
Data
hex
mnemonic w/symbols
5448
xx48H
5349
5349H
4949
49xxH
4953
xx53H
4920
4920H
2020
20xxH
2049
xx49H
2053
2053H
5353
53xxH
5320
xx20H
454D
454DH
4D4D
4DxxH
4D45
xx45H
5353
5353H
5353
53xxH
step
display
The resulting display shows MVN instruction moves the "THIS IS
MESSAGE A" message to the destination locations.
To list the previous lines of the trace, press the <PGUP> or <PREV>
key.
Enter the following command to display count information relative to
the trigger state.
display trace count absolute <RETURN>
Opcode or Status
data write
mx
data read
mx
data write
mx
data write
mx
data read
mx
data write
mx
data write
mx
data read
mx
data write
mx
data write
mx
data read
mx
data write
mx
data write
mx
data read
mx
data write
mx
Emulation trace complete______........
modify
break
end
time count
relative
4.00
uS
8.00
uS
8.00
uS
4.00
uS
8.00
uS
8.00
uS
4.00
uS
8.00
uS
8.00
uS
4.00
uS
8.00
uS
8.00
uS
4.00
uS
8.00
uS
8.00
uS
---ETC--