b) Operation
• Remove the protective cap from the probe tip.
• Turn the endoscope on.
• Set the brightness of the camera LEDs. Information on controlling the LED brightness can be
found in the operating instructions of the connected endoscope.
• Turn off the endoscope after you have finished using it.

Care and cleaning

• Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these may
damage the casing or cause the product to malfunction.
• Use the enclosed cleaning kit to clean the camera head.
• Use a soft, antistatic, lint-free cloth to clean the product.
• After inserting the camera neck into liquid, rinse it thoroughly with clean water and dry it
before storing it for next use.
• Place the protective cap onto the probe tip when you are not using the product.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste. Always dispose of the product according to the relevant statutory
regulations.
You thus fulfil your statutory obligations and contribute to the protection of the environment.

Technical data

Power supply ................................ 3.7 V/DC
Camera Ø (exterior) ...................... 14 mm
Probe length ................................. 1.2 m
Depth of focus .............................. 3 - 60 cm
Field of view .................................. 57°
Resolution ..................................... 640 x 480 px
Lighting ......................................... 2 LEDs (white)
Lighting level ................................. max. 2900 lx (at 20 mm distance)
Min. bending radius ...................... >9 cm
Protection class ............................ IP67 (camera and goose neck)
Electrical safety ............................ Measurement categories CAT III 1000 V / CAT IV 600 V
according to EN 61010-1 (in a dry environment)
Operating/storage temperature .... -20 to +60 °C
Operating humidity ....................... <95% relative air humidity, non-condensing
(does not apply to measurement categories CAT III 1000 V
/ CAT IV 600 V)
Storage humidity ........................... <95% relative humidity, non-condensing
Weight .......................................... approx. 240 g
Suitable for endoscope main devices:
BS-1000T - Item no. 123319
BS-1500T - Item no. 1340787
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or capture in
electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2018 by Conrad Electronic SE.
*1590115_v1_0318_02_hk_m_en

Advertisement

Table of Contents
loading

This manual is also suitable for:

4016139316987

Table of Contents