5.9.1 Shared Buffer Latch Error Codes and Extended Data

This table defines the meaning of failure status bytes 2 and 3 of the
store loop adapter failure status bytes.
+------------------------------------------------------------------------+
¦ Table
5-3. Shared Buffer Latch Error Codes and Extended Data
+------------------------------------------------------------------------¦
¦ Byte
¦ Byte 3
¦
¦ 2
¦ Extended
¦
¦ Error ¦ Data
¦ Definition
¦ Code
¦
¦
+-------+------------+---------------------------------------------------¦
¦ 00
¦ 00
¦ No errors detected
+-------+------------+---------------------------------------------------¦
¦ 01
¦ Store loop ¦ The store loop adapter microprocessor was not at
¦
¦ adapter
¦ a "ready and not enabled" condition after initial ¦
¦
¦ system
¦ POR was complete.
¦
¦ status
¦
¦
¦ byte.
See ¦
¦
¦ page 5.11. ¦
+-------+------------+---------------------------------------------------¦
¦ 02
¦ Store loop ¦ A level 7 software interrupt was not received
¦
¦ adapter
¦ when expected.
¦
¦ interrupt
¦
¦
¦ flag byte. ¦
¦
¦ See page
¦
¦
¦ 5.14.
¦
+-------+------------+---------------------------------------------------¦
¦ 03
¦ Store loop ¦ A level 7 hardware interrupt was not received
¦
¦ adapter
¦ when expected.
¦
¦ system
¦
¦
¦ status
¦
¦
¦ byte.
See ¦
¦
¦ page 5.11. ¦
+-------+------------+---------------------------------------------------¦
¦ 04
¦ Shared
¦ The 4684 microprocessor was unable to find the
¦
¦ buffer
¦ shared buffer after initial POR was complete.
¦
¦ request
¦
¦
¦ byte.
See ¦
¦
¦ page 5.12. ¦
+-------+------------+---------------------------------------------------¦
¦ 05
¦ Store loop ¦ The store loop adapter microprocessor was not at
¦
¦ adapter
¦ a "ready and not enabled" condition after initial ¦
¦
¦ system
¦ POR was complete.
¦
¦ status
¦
¦
¦ byte.
See ¦
¦
¦ page 5.11. ¦
+-------+------------+---------------------------------------------------¦
¦ 06
¦ Shared
¦ The 4684 microprocessor was unable to return the
¦
¦ buffer
¦ shared buffer to the store loop adapter
¦
¦ request
¦ microprocessor after initial POR was complete.
¦
¦ byte.
See ¦
¦
¦ page 5.12. ¦
+-------+------------+---------------------------------------------------¦
¦ 07
¦ Store loop ¦ The 4684 microprocessor was unable to acquire the ¦
¦
¦ adapter
¦ shared buffer for a software POR request.
¦
¦ system
¦
¦
¦ status
¦
¦
¦ byte.
See ¦
¦
¦ page 5.11. ¦
+-------+------------+---------------------------------------------------¦
¦ 08
¦ Shared
¦ The 4684 microprocessor was unable to find the
¦
¦ buffer
¦ shared buffer after acquiring it for a software
¦
¦ request
¦ POR request.
¦
¦ byte.
See ¦
¦
¦ page 5.12. ¦
+-------+------------+---------------------------------------------------¦
¦ 09
¦ Store loop ¦ A level 7 hardware interrupt was not received
¦
¦ adapter
¦ from a software POR request.
¦
¦ system
¦
¦
¦ status
¦
¦
¦ byte.
See ¦
¦
¦ page 5.11. ¦
+-------+------------+---------------------------------------------------¦
¦ 0A
¦ Store loop ¦ The store loop adapter microprocessor internal
¦
¦ adapter
¦ diagnostic test failed to complete during the
¦
¦ system
¦ software POR.
¦
¦ status
¦
¦
¦ byte.
See ¦
¦
¦ page 5.11. ¦
+-------+------------+---------------------------------------------------¦
¦ 0B
¦ Shared
¦ The alternate shared buffer failed.
¦
¦ buffer
¦