Page 1
Came Cancelli Automatici è una società certificata ISO 9001 per il sistema di gestione della qualità aziendale e ISO 14001 per il sistema di gestione ambiantale. Came progetta e produce interamente in Italia. INSTALLATION MANUAL RBM84 - HW English...
RBM84 - Hardware and connections SUMMARY TOPIC PAGE What RBM84 is ....................................3 The uses of RBM84 ..................................4 What RBM84 can do ..................................5 Technical data for individual components ............................5 Schematic diagram ...................................6 RBM84 base board - description ..............................7 RBM84 base board - description ...............................8 TOR100 base board - description ..............................9 RBM84 Turnstile confi...
PC30 should instead be installed in the vicinity of the computer (max 5 m), as it is an indispensable tool for programming the control devices connected. PC30 unites all the decoders required to store all compatible Came control devices: - Transmitters of the series Atomo, Tam, Top, TWIN (in TOP, TAM mode).
RBM84 - Hardware and connections The uses of RBM84 The RBM84 system is able to fi t into any context that requires access control for: - access authorisation - entrance/exit recording - entrance/stay/exit monitoring - entrance and exit activation and selection - controlling parking time and costs - locking/releasing the system and/or providing real-time authorisation - allow system centralised management...
RBM84 - Hardware and connections What RBM84 can do The following features are off ered for all these applications and for any system that includes access and/or exit points that require authorisation/control/recording/monitoring: For the system as a whole Confi guration - within the system - of diff erent control devices, even for the same automation: a keyboard selector, transmitter or transponder cards (magnetic or swipe), home control systems (Wave).
è una società certificata ISO 9001 per il sistema di gestione della qualità aziendale e ISO 14001 per il sistema di gestione ambiantale. Came progetta e produce interamente in Italia. RS232 cable Max 5 m Max 1000 m PSINS PSSRV Cables x 1.5 mm²...
RBM84 - Hardware and connections RBM84 base board - description Power supply terminals for 230V A.C. board Connection terminals for digital input devices Power supply safety fuse Connection terminals for slave devices Circuit safety fuse "Circuit active" alert LED Connection terminals for transponder sensors (TSP00) and 10.
RBM84 - Hardware and connections RBM84 Turnstile confi guration The turnstile must be confi gured and numbered via functions 11 and 12 in order to perform operations in the RBM84 system, as shown hereafter. Function 11: Stand Alone or OnLine mode In Stand-Alone (OFF) the turnstile works automatically, while On-Line (ON) the turnstile is connected and controlled by RBM84.
RBM84 - Hardware and connections PC30 - description 12V A.C. power supply TSTO2 card memorisation area (magnetic stripe and swipe RS232 serial port for PC connection cards) Rbm84 connection terminals (RS485 serial port) 10. "Voltage present" indicator LED 12V A.C. power supply 11.
RBM84 - Hardware and connections RBM84 connection <----> PC30 <----> Personal Computer Port 1.5 m cable for RS232 serial ports PC30 supplied with connectors RS232 serial port Cable NOT INCLUDED RBM 84 recommended type: unshielded 12V AC power supply for 230V A.C. power supply - 50÷60Hz multipair cable 800 mA current draw (CAT 5 - U/UTP - AWG24)
RBM84 - Hardware and connections RBM84 connection <----> Modem <----> Personal Computer Caution! The phone number entered to place a call is that of the digital modem connected to RBM84 Integrated or external modem for remote control Telephone Line RBM84 RS232 Modem Null Cable MODEM...
RBM84 - Hardware and connections RBM84 connection <----> REM (single segments) RBM 84 Cable NOT INCLUDED recommended type: unshielded multipair cable (CAT 5 - U/UTP - AWG24) see Annex A Connecting to A segment: RBM84 is at the end of the cable path Each Rem is identifi...
RBM84 - Hardware and connections RBM84 connection <----> REM (two segments) RBM 84 Cable Cable NOT INCLUDED NOT INCLUDED recommended type: recommended type: unshielded unshielded multipair cable multipair cable (CAT 5 - U/UTP - AWG24) (CAT 5 - U/UTP - AWG24) see Annex A see Annex A Two SEGMENT connection: RBM84 can be...
RBM84 - Hardware and connections Connection RBM84/REM <----> Sensor: remote control RBM 84 ATOMO series AT01 Connect the receiver R501N (that includes the plug-in radio frequency card AF43S ) to the RBM84. The antenna Top- AT02 A433N is also connected to the receiver. TOP-A433N R501N AT04...
RBM84 - Hardware and connections Connection RBM84/REM <----> Sensor for magnetic swipe cards RBM84 TST02 Magnetic card R700 CANCELLI AUTOMATICI LT001 Swipe reader for magnetic cards Maximum distance: 50m Black=GND Red=S1 TST02 Magnetic card R700 CANCELLI AUTOMATICI LT001 Swipe reader for magnetic cards Maximum distance: 50m Black=GND...
RBM84 - Hardware and connections Connection RBM84/REM <----> Digital input contacts Rbm84 Capable of connecting alarms, magnetic coils, locks, etc. Capable of connecting alarms, magnetic coils, locks, etc.
RBM84 - Hardware and connections Connection RBM84 <----> Traffi c lights 230 VAC ① = Black ② = Brown ③ = Blue "Partial" traffi c lights associated to diff erent levels or sectors, up to 8 at most, where 4 are controlled by REM, which in turn is controlled by the software supplied.
2, 12V x 1.2Ah batteries charger is not connected. (NOT INCLUDED). Batteries + battery charger RBM84 Procure a casing (e.g.: Came code 119RIR315 panel casing) to house the batteries and the battery charger board. Connection cables must be 2 metres long at most.
RBM84 - Hardware and connections DIP setting on REM connected in succession REM n° 29 REM n° 45 REM n° 30 REM n° 46 REM n° 1 REM n° 15 REM n° 31 REM n° 47 REM n° 2 REM n° 16 REM n°...
RBM84 - Hardware and connections Dip switch RBM84 - Function selection Lock-out user with zero credit function Dip 2 ON....A user with 0 credit may enter: must purchase additional credit to exit. Users with negative credit are denied access. Dip 2 OFF....A user with 0 credit, denied access. N.B.
Page 28
Came S.p.A. Came S.p.A. Via Martiri Della Libertà, 15 Via Cornia, 1/b - 1/c 31030 Dosson di Casier Dosson di Casier 33079 Sesto al Reghena Sesto al Reghena Treviso Treviso - Italy Pordenone Pordenone - Italy (+39) 0422 4940 (+39) 0434 698111...