HBM TB1A Mounting Instructions page 15

Hide thumbs Also See for TB1A:
Table of Contents

Advertisement

Available languages

Available languages

TB1A
CAUTION
It is essential to keep to the maximum thread reach in the mounting
flange (as per Table 4.1) ! Otherwise, considerable measurement errors
might occur or the transducer might suffer damage.
Nominal
Fastening
torque
bolts (Z)
measuring
(NVm)
body
100
M6
200
mM8
500
M12
1k
M12
2k
M14
5k
M18
10k
M18
Table 4.1: Fastening bolts
1)
If screws of Class 12.9 are not available, Class 10.9 screws (400 N⋅m tightening torque)
can be used. The permissible limiting torque is reduced then to 120 % referred to M
Fig. 4.4: Installation example
A0162 7.0 en/de/fr
Fastening bolts
property class
10.9
1)
12.9
Max. thread reach Y
Z
Maximum thread reach
(Y) of the screws in the
mounting flange
(mm)
7.5
11
18
18
18
33.5
33.5
Torque measuring disc
15
Prescribed
tightening torque
(NVm)
14
34
115
115
185
400
470
.
N