Preparing for use
Mounting the water selection unit
When you exchange the adapter, beware the screw thread of the tap is
sharp.
-
Before you install the water purifier, make sure all tap adapters you
require are present.
-
The tap must have a diameter of 13mm-25mm.
-
Determine what type of tap you have and select the appropriate
tap adapter.
-
The tap adapters supplied make the water purifier suitable for almost
any kitchen tap. However, the water purifier may not fit some
uncommon types of taps.
-
The tap water pressure has to be between 0.7kgf/cm² and 3.5kgf/cm².
If you use the water purifier at a water pressure below this range, the
filtered water flow is either extremely low or there is no flow at all.
On the other hand, if the water pressure exceeds this range, the
water purifier gets damaged.
installation A-type adapter
-
For taps with a round spout with a diameter of 16mm, 17.5mm or
19mm (Fig. 2).
1
Remove the attachment nut and the adapter from the water
selection unit (Fig. ).

Pass the attachment nut over the tap spout (Fig. ).

Place the matching adapter (A-type) over the tip of the spout. The
16mm adapter is attached to the water selection unit when you
unpack it. Replace this adapter with the 1.5mm adapter or 19mm
adapter to fit the diameter of your tap (Fig. 5).

Tighten the attachment nut firmly onto the water
selection unit (Fig. 6).
installation B-type adapter
-
For taps with an aerator (threaded on the outside) (Fig. 7).
EnglisH
9