Fireplace Installation
Figure 4
within the framing. Adjust as
required.
6. Drive four supplied mounting
screws through the four
mounting holes located on the
inside surface of the fireplace
chassis, into wall studs
(Figure 4).
120V Installation - Direct Wire
!
NOTE: The unit is designed
to be hardwired to a power
source and should not have
a cord installed to allow the
unit to be plugged into a wall
receptacle.
Use two conductor, non-metallic
sheath cable with ground wire
(3 wires total) for the incoming
power supply.
CAUTION: Use the
appropriate wire to meet local
Mounting Holes
and national electrical codes
for rated power consumption.
• Cut the wire to an appropriate
length.
• Connect the L wire from the
unit to the live wire from the
power supply with a wire nut.
• Connect the N wire from the
unit to the neutral wire from the
power supply with a wire nut.
• Connect the G wire from the
unit to the ground wire from
the power supply with a wire
nut or attach the grounding
wire to the cover with the
provided grounding screw, by
placing the wire in-between
screw and lock washer and
tighten (Figure 3).
• Ensure that all wires are
secure and do not protrude
Flame
Panel
9