Fireplace Installation
Figure 5
Glass
Openings
Partially
Reflective Glass
screw and lock washer and
tighten (Figure 3).
• Ensure that all wires are
secure and do not protrude
past the flame panel, so as
not to be visible after final
assembly.
• Continue to the final assembly
instructions.
240V Installations
Use three conductor, non-metallic
sheath cable with ground wire
(4 wires total) for the incoming
power supply on fireplace inserts.
CAUTION: Use the
appropriate wire to meet local
and national electrical codes
for rated power consumption.
• Connect the L1 wire from the
unit to the L1 wire from the
Retaining
Bracket
Media Tray
power supply with a wire nut.
• Connect the L2 wire from the
unit to the L2 wire from the
power supply with a wire nut.
• Connect the N wire from the
unit to the neutral wire from the
power supply.
• Connect the G wire from the
unit to the ground wire from the
power supply with a wire nut
or attach the grounding wire
to the cover with the provided
grounding screw, by placing
the wire in-between screw
and lock washer and tighten
(Figure 3).
• Ensure that all wires are
secure and do not protrude
past the flame panel, so as
not to be visible after final
assembly.
11