Restore To Factory Setting; Home Automation Clusters For Z821 - netvox ZigBee 821 User Manual

Wireless power meter
Table of Contents

Advertisement

Step1. Press and hold the Binding Key for 20 seconds. The status indicator will flash 4 times.
Step2. After releasing the Binding Key, press the Match Key within 2 seconds to complete the reset.

5-6. Restore to Factory Setting

To restore it to factory setting, please follow the steps:
Step1. Press and hold the Binding Key for 15 seconds. The status indicator will flash 3 times.
Step2. After releasing the Binding Key, press the Match Key within 2 seconds to complete the restore.

6. Home Automation Clusters for Z821

A cluster is a set of related attributes and commands which are grouped together to provide a specific function. A
simple example of a cluster would be the On/Off cluster which defines how an on/off switch behaves. This table
lists the clusters which are supported by Z821.
Cluster ID for Z821
Server side
Basic(0x0000)
Identify (0x0003)
Commissioning(0x0015)
Simple Metering(0x0702)
Attribute ID for Simple Metering (0x0702)
ATTRID
Current (0xE000)
Voltage (0xE001)
Power (0xE002)
Energy (0xE003)
This lists the attributes of the basic information.
Identifier
Name
0x0000
ZCLVersion
Consumption Awareness
InstananouesDemand (0x0400)
CurrentSummationDeliver (0x0000)
Type
Range
8-bit
0x00 –0xf
Unsigned
f
integer
9
Client side
None
Access
Default
Read
0x03
only
Mandatory
/ Optional
M