External Alarms
External Alarms lists Alarm #1 – #6. Select an alarm to provision it individually. The following
options are supported for each of the alarm inputs:
• Name: (Text string up to 40 characters long)
• Enable: (Yes, No)
• Level: (Critical, Major, Minor, Alert, Info)
• Detect: (Closed or Open connection on alarm input)
An additional Status field indicates current alarm state (Active or Inactive).
Service State
Service State options include the following:
Do not change the service state to Out of Service – Unassigned if
configuring the RMM remotely and the management link to the
remote SCU runs through the RMM.
• In Service (data transfer and alarms are enabled)
• Out of Service – Maintenance (still passes data, but alarms are suppressed)
• Out of Service – Unassigned (data transfer and alarms are disabled)
Restore Factory Defaults
Restore Factory Defaults resets all provisioned options to default settings.
Provisioning options are outlined in
61181019L1-5C
CAUTION
Table 3
on page 6.
Menu Structure
17