Remote Management Module Installation and Maintenance Practice
Front Panel LEDs
The RMM provides front panel LEDs to display status information.
status descriptions.
LED
Indication
Description
Off
Lack of power or power failure
PWR
Green
Power up and initialization OK
Flashing
User menu interface is active
Yellow
Module Out of Service – Unassigned (OOS-UAS), or
Out of Service – Maintenance (OOS-MA)
Red
Hardware or firmware failure
Off
Module OOS-UAS
LAN
Green
Port operational without any alarms
Flashing
Data traffic present
Red
Alarm condition on port
Off
Module OOS-UAS
WAN
Green
Port operational without any alarms
Flashing
Data traffic present
Yellow
Port in test mode
Red
Alarm condition on port
Initial Installation Provisioning Options
Upon initial installation of the RMM, the unit is provisioned according to factory default
settings, shown in
Table
All provisioning is handled through the System Controller Unit (SCU) communication link.
The unit retains provisioning data in a nonvolatile memory device in case of a loss of power to
the module.
Provisioning Option
CSU Code Loop Detect
DS1 Timing Source
DS1 Network Source
DS1-X Line Build Out
DSX-1 Line Coding
External Alarms
Service State
6
Table 2. Front Panel LEDs
3.
Table 3. Default Provisioning Options
Settings (Default in BOLD)
Enabled; Disabled
Recovered; Local
MUX; DSX-1
0 – 133 ft; 133 – 266 ft; 266 – 399 ft; 399 – 533 ft; 533 – 655 ft
B8ZS; AMI
Alarm #1 – 6
In Service; Out of Service – Unassigned; Out of Service – Maintenance
Table 2
lists the LEDs and
61181019L1-5C