Kusam-meco KM 66 Operation Manual

Kusam-meco KM 66 Operation Manual

Voltage tester

Advertisement

Quick Links

LIST OF PRODUCTS
*
Digital Multimeter
Digital AC & AC/DC Clampmeter
*
AC Clamp Adaptor
*
AC/DC Current Adaptor
*
*
Transistorised Electronic Analog & Digital
Insulation Resistance Testers(upto 10 KV)
Digital Sound Level Meter & Sound Level
*
Calibrator
Digital contact & Non-contact Type
*
Tachometer
Digital Non-contact (infrared) Thermometer
*
*
Thermo Hygrometer
*
Thermo Anemometer
*
Wood & Paper Moisture Meter
Distance Meter
*
*
Digital Hand Held Temperature Indicators
*
Digital Lux Meter
*
Network Cable Tester
*
Power Factor Regulator
*
Maximum Demand Controller/Digital Power
Meter
*
Earth Resistance Tester
An ISO 9001:2015 Company
G 17, Bharat Industrial Estate, T. J. Road, Sewree (W),
Mumbai-400015. INDIA
Sales Direct: 24156638
Tel.:
(022)2412 4540, 2418 1649
E-mail : kusam_meco@vsnl.net, Website : www.kusam-meco.co.in,
®
Fax:
2414 9659
www.kusamelectrical.com
VOLTAGE TESTER
MODEL
KM 66 / KM 69
OPERATION
MANUAL
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KM 66 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kusam-meco KM 66

  • Page 1 AC Clamp Adaptor VOLTAGE TESTER AC/DC Current Adaptor Transistorised Electronic Analog & Digital MODEL Insulation Resistance Testers(upto 10 KV) KM 66 / KM 69 Digital Sound Level Meter & Sound Level Calibrator Digital contact & Non-contact Type Tachometer Digital Non-contact (infrared) Thermometer...
  • Page 2: Table Of Contents

    ® ® TABLE OF CONTENTS TITLE PAGE VOLTAGE TESTER Safety Information..........01 MODEL - Electrical Symbols...........03 KM 66 / KM 69 Features.............05 General Specifications........06 Electrical Specification ........08 Product Description ........11 Operation............12 Maintenance............21 Test Certificate ..........23 Warranty ............24 30mA 230V 1000 1000...
  • Page 3 600V, AC & DC. It also meets water and dust Disconnect the test leads from the test points protection IP65 per outdoor type requirements of before changing functions. IEC61243-3:2014. It is, however, not intended to KUSAM-MECO Feb 2018 KUSAM-MECO Feb 2018...
  • Page 4: Electrical Symbols

    100 kΩ, may not permit to clearly indicate the equipment for industrial use and some other absence of operating voltage in case of presence of equipment such as stationary motors with interference voltage. permanent connection to the fixed installation. KUSAM-MECO Feb 2018 KUSAM-MECO Feb 2018...
  • Page 5: Features

    — LCD indication (KM 69), — Overload Protection : 1000VDC & VAC rms. — AC-Detection Shaker (KM 69) — Low Battery : Below approx. 2.6V; — RCD Leakage-Path (KM 69) — RST Phase Rotation Detection (KM 69) KUSAM-MECO Feb 2018 KUSAM-MECO Feb 2018...
  • Page 6: Electrical Specification

    @ 23°C ± 5°C. Maximum Crest Factor <2:1 at full — Power Consumption (typical) : scale & <4:1 at half scale, and with frequency KM 66 : 1mA for Power-on ready 40mA for components fall within the tester specified Buzzer on @ Continuity or EF function frequency bandwidth for non-sinusoidal waveforms KM 69 : 2.7mA for Power-on ready &...
  • Page 7 Open Circuit Voltage : 0.7 DC Typical In the event of a full continuous 5 second activation Audible Threshold : between 1MW & 1.5MW (KM 66) interval, the protection PTC will heat up and affect the between 500KW & 750KW (KM 69) load current magnitude thereafter.
  • Page 8: Product Description

    As illustrated, connect test probes to voltage 9. Input Jack(-) for source and observe indication. Do not cover the Detachable Black indicating LEDs (and also the LCDs on KM 69) and test probe (Common ground reference) KUSAM-MECO Feb 2018 KUSAM-MECO Feb 2018...
  • Page 9 WARNING thereafter. Allow cooling for 120 seconds before the next activation then. This feature is to warn the user of the presence of a voltage above the ELV limit, not for its evaluation. KUSAM-MECO Feb 2018 KUSAM-MECO Feb 2018...
  • Page 10 (Ö3 times to that of the other legs) with respect to earth-ground, and use it as the Reference-Phase R for Black probe (L1) connections. High-leg Δ-connection systems have a center-tapped neutral connected to earth-ground. KUSAM-MECO Feb 2018 KUSAM-MECO Feb 2018...
  • Page 11 Non-contact EF flash AC-Detection Shaker KM 69 The shaker turns on when significant ACV is being detected via the test probes. KUSAM-MECO Feb 2018 KUSAM-MECO Feb 2018...
  • Page 12 , t h e C o n t i n u i t y - L E D t u r n s o n accompanied with a continuous beep sound indicate a complete circuit. KUSAM-MECO Feb 2018 KUSAM-MECO...
  • Page 13: Maintenance

    60 days, remove Replace the batteries. Re-fasten the screws. the batteries and store them separately. The tester uses 1.5V AAA Size (NEDA 24A OR IEC LR03) Alkaline Battery x 2 KUSAM-MECO Feb 2018 KUSAM-MECO Feb 2018...
  • Page 14: Test Certificate

    ® ® WARRANTY MUMBAI Each “KUSAM-MECO” product is warranted to be free TEST CERTIFICATE from defects in material and workmanship under normal use & service. The warranty period is one year (12 VOLTAGE TESTER months) and begins from the date of despatch of goods. In...