☛ Confirm that the Freedom Lite is showing in the device list (top of the menu structure) as per below
☛ Freedom Lite → Parameters → Confirm that the Charge Current Limit and Discharge Current Limit
are as per the Lite specifications (Note: if the battery is fully charged the CCL may be reduced. Check
that the voltage target is within the range 54.8V to 55.8V (Note: below about 95% SoC the value
reflected should be 55.7 or 55.8V. For a fully charged battery this value should range from 55.0V to
55.8V depending on the state of balancing of the cells in the Lite.
☛ Confirm that DVCC is forced on at: Settings → DVCC