6.2.5 Setting a (Mask) area

A measured range is called an "area". The area is displayed in green. A function that does not allow the
AX40 execute inspection within a masked part of an area is called a "mask function", and the part in
which inspection is not allowed is called a "mask area". The mask area is displayed in yellow. The shapes
of an area and a mask area include rectangle, circle, polygon (up to 16 peaks), plane scan (rectangle),
line scan (line). The area shapes you can set differ depending on the checker type.
Setting an area
A setting example for binary window checker is explained below.
1.
Select "Area" from the inspection menu.
The menu for area setting is displayed.
2.
Select "Change Shape" and press the ENTER key.
The list of the shapes that is selectable for the selected checker is displayed. The
shape that is currently selected is deactivated.
3.
Select "Rectangle", "Circle", or "Polygon".
4.
Select "Change".
An area is displayed on the screen. Change its location and size. See page 40 for
more information.
5.
Set the location and size of the areas and press the C key.
The checker menu is displayed.