Parameter
Number
5
One shot timer:
Writing to this parameter prompts the
sensor to send a wakeup notification one
time after this parameter's number of
seconds. After which it is reset back to 0.
6
The number of milliseconds waiting for a
Supervisory Report response to a
Supervisory Get encapsulated command
from the sensor before attempting a retry.
Notification Command Class, V8
Sensor Condition
Door/Window Open
Door/Window Close
Sensor Case Removed
Date:
Description
Notification Report
Type: Home Security 0x07
State: Intrusion 0x02
Notification Report
Type: Home Security 0x07
State: Previous Events Cleared 0x00
Event parameter: 0x02
Notification Report
Type: Home Security 0x07
State: Tampering Product Covering Removed 0x03
Ring Alarm Contact Sensor User Manual
Version: 0.1
Number
of
Default
Bytes
2
0 (0x00)
5 (0x05)
2
1500
500 (0x1F4)
(0x5DC)
Command Class and Value
Min
Max
65535
(0xFFFF)
5000
(0x1388)
Association Group
1 (Lifeline)
1 (Lifeline)
1 (Lifeline)
Page:
- 8 -
Format
0x01
Unsigned
0x01
Unsigned