Schweigen GA-900S Instruction Manual

Undermounted rangehoods
Hide thumbs Also See for GA-900S:

Advertisement

Quick Links

UNDERMOUNTED RANGEHOODS
INSTRUCTION MANUAL
Installation / Operation / Maintenance
GA-900S
GA-1200S
KLS-9GLASSBLKS
KLS-9GLASS
(10.2020 / V8)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GA-900S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Schweigen GA-900S

  • Page 1 UNDERMOUNTED RANGEHOODS INSTRUCTION MANUAL Installation / Operation / Maintenance GA-900S GA-1200S KLS-9GLASSBLKS KLS-9GLASS (10.2020 / V8)
  • Page 2 INDEX Welcome Important Safety Information Description Operation Cleaning and Maintenance Installation Condensation Information Troubleshooting Technical Specifications Disclaimer Page 2...
  • Page 3 WELCOME Thank you for purchasing this Schweigen IN appliance. IMPORTANT! To achieve the optimal performance from your The appliance should only be appliance, and to avoid the risk of accident or operated when you have read and damage, it is essential to read this manual before understood this manual thoroughly.
  • Page 4: Important Safety Information

    IMPORTANT SAFETY INFORMATION Please read the instructions carefully. Only then Flames beneath the pan must be contained at all will you be able to operate your appliance safely times and cannot exceed the width of the pan in and correctly. Retain the instruction manual for use.
  • Page 5: Before Installation

    IMPORTANT SAFETY INFORMATION BEFORE INSTALLATION Schweigen will not be responsible for any installations executed by non-qualified technicians We recommend this appliance be installed or that fail to heed the applicable legislation on repaired by a qualified Schweigen Home Appliances electrical safety.
  • Page 6: Product Use

    IMPORTANT SAFETY INFORMATION PRODUCT USE MAINTENANCE AND SERVICE This product is designed for household use and The rangehood surface should be cleaned with soft should not be used for commercial applications. cloth and non-corrosive detergent. Do not leave the rangehood wet after cleaning or use, please After use, always ensure that all controls are in keep rangehood dry.
  • Page 7 DESCRIPTION KLS-9GLASS and KLS-9GLASSBLKS GA-900S and GA-1200S 1. Female plug, to be connected to Isodrive motor 1. Female plug, to be connected to Isodrive motor ® ® system only system only 2. Male Plug, to be connected to main power 240V 2.
  • Page 8: Operation

    OPERATION OPERATION For models KLS-9GLASS and KLS-9GLASSBLKS. The rangehood has a 4-speed electronic keypad. Speed control usage suggestions: • Low speed for simmering. • Medium speed for light cooking. • High speeds for heavy frying or heavy cooking. Electrical Touch Keypad To obtain the best performance, switch the F.- Timer: When the timer mode is in operation, rangehood on a few minutes prior to cooking and...
  • Page 9 OPERATION OPERATION For models, GA-900S and GA-1200S The rangehood has a 4-speed electronic keypad. Speed control usage suggestions: • Low speed for simmering. • Medium speed for light cooking. • High speeds are for heavy frying or heavy cooking. Electrical Tactile Keypad To obtain the best performance, switch the D.- Reduce speed: This button reduces the...
  • Page 10: Cleaning And Maintenance

    CLEANING AND MAINTENANCE WARNING Always switch off and disconnect power to the rangehood before cleaning. The manufacturer is exonerated from all responsibility in the event of fire due to poor maintenance of the filters and rangehood. Cleaning and user maintenance shall not be made by children without supervision. FILTERS the rangehood (removing the pins from the front guide), ease down slightly and remove.
  • Page 11 CLEANING AND MAINTENANCE SURFACES Do not pour any liquid directly onto the rangehood, apply to a soft cloth first. The surface of the rangehood can be cleaned with The cloth must have no buttons, zips or fasteners warm soapy water and a soft sponge / cloth. that can scratch the surface.
  • Page 12: Replacing The Led Bulb

    CLEANING AND MAINTENANCE WARNING Always switch off and disconnect the power cord before replacing any light bulbs. Failure to do so may cause serious injury. Please be aware that the light bulb will retain heat for a short period of time after being switched off. Your rangehood may have multiple light types, please refer to the pictures below for light replacement instructions.
  • Page 13: Replacing The Strip Lighting

    CLEANING AND MAINTENANCE WARNING Always switch off and disconnect the power cord before replacing any light bulbs. Failure to do so may cause serious injury. Please be aware that the light bulb will retain heat for a short period of time after being switched off. We recommend an approved Technician performs this task TYPE 4 (LED Strip TL): Type 4 —...
  • Page 14: Installation

    INSTALLATION RANGEHOOD SIZE VS COOKTOP SIZE In addition to the size, the height of the rangehood above the cooktop is important to obtain the best performance. INADEQUATE ADEQUATE OPTIMAL Rangehood smaller than Rangehood same size as Rangehood larger than cooking zone cooking zone cooking zone Page 14...
  • Page 15 INSTALLATION OVERHEAD CABINET RANGEHOOD INSTALLATION POSITION It is important to consider the benchtop and overhead cabinetry depth before installing the rangehood. The information below is to be used as a guide only, drawings are not to scale and do not account for all circumstances.
  • Page 16: Mounting Laws And Regulations

    Note: If the instructions for the gas cooktop specify a greater distance, this must be taken into account. RECOMMENDED INSTALLATION HEIGHT FOR INDUCTION COOKTOP To help avoid condensation, particular to cooking with an induction cooktop, Schweigen recommends a minimum height of 700mm. Refer to page 24 for further information.
  • Page 17 INSTALLATION Installation for KLS-9GLASS and KLS-9GLASSBLKS IMPORTANT Please read the installation guide thoroughly prior to installation. These models have a different method of installation compared to standard undermounts. Step 1 Fix the rangehood mounting supports (A) to the sides of the cabinet (B). NOTE: The brackets need to be levelled and secured, in order to hold the entire weight of the undermount.
  • Page 18 INSTALLATION Step 3 Fit the undermount in place, using the installation screws provided (E). Protecting the Cabinet Door — Optional A reversible “L” shaped profile is provided for optional cabinet door (D) protection. “L” shaped profile Step 4 Only install the reducer if you are connecting the 650 motor.
  • Page 19 INSTALLATION Installation for GA-900S and GA-1200S Step 1 Cut the cabinetry to the correct size in order to fit the undermount, see figure on the right. NOTE: It is always best to use the rangehood as a cutting guide, not the cabinet cut out diagram as this is only a guide.
  • Page 20 INSTALLATION Step 4 Fix the undermount to the cabinetry with appropriate screws, using the pre-drill holes in the undermount body (C). Step 5 Once (D) has been firmly attached, fix the fascia (A) to the rangehood (D) the magnets (B) will hold the fascia in place.
  • Page 21 INSTALLATION Step 6 Re-attach the fascia by securing it with 4 x locking screws (E). Step 7 Re-install the filters. IMPORTANT Please ensure all plastic protection on the rangehood and filters are removed before use. Page 21...
  • Page 22 INSTALLATION Please DO NOT crush or kink the ducting. 1. Crushed or kinked ducting creates sharp corners that creates turbulence. This reduces the size and efficiency of the ducting, lowers extraction and may cause excessive noise. 2. Sweeping curves and taut ducting reduces resistance and turbulence.
  • Page 23: System Overview

    INSTALLATION SYSTEM OVERVIEW 1. Isodrive Motor ® 2. Roof Seal Kit (Dektite) (Not Supplied)* 3. Support Straps (Not Supplied)* 4. Attach Flexi Duct to Bell-Mouth Adaptor using ring clamp. Please DO NOT rip the ducting. 5. Isodrive Motor Power Lead (Male Plug) ®...
  • Page 24: Troubleshooting

    TROUBLESHOOTING COOKING WITH INDUCTION How to reduce the possibility of condensation forming: COOKTOPS • Ensure the rangehood is installed by a qualified Cooking with an induction (or similar) cooktop, professional, carefully following the installation may produce condensation on the rangehood. guide.
  • Page 25 TROUBLESHOOTING Before you contact the technical service department, make sure that the product IMPORTANT is plugged in and power is supplied. Never attempt to repair this • Do not take any action that will damage appliance by yourself. Always the product. refer to a qualified Service Technician.
  • Page 26: Faulty Installation

    0800 200 510 FAULTY INSTALLATION It is not the responsibility of Schweigen to rectify any incorrect installations. A service call out fee will be charged for any Schweigen technician that attends a call, whereby it is established that the fault is due to an incorrect installation or non-manufacturing fault.
  • Page 27: Technical Specifications

    TECHNICAL SPECIFICATIONS KLS-9GLASS, KLS-9GLASSBLKS Light towards the front of the rangehood 28.8 Thickness of glass- 5mm Model: KLS-9GLASS, KLS-9GLASSBLKS Feeding Voltage: 220-240V 50Hz Max Lamp Power: 1 x LED Strip 726mm long 3.36W 12V 4200k Page 27...
  • Page 28 TECHNICAL SPECIFICATIONS GA-900S CONFIDENTIAL Drawn by: Drawn by: D. Izquierdo D. Izquierdo Material: Material: Thic Model: GA-900S Model: SCHWEIGEN Model: SCHWEIGEN Drawn by: D. Izquierdo GA-900S Code: Feeding Voltage: 220-240V 50Hz Description: Description: GA-900 GA-900 Material: Thickness Weight: Qty. Max Lamp Power: 2 x GLED Square 55 x 55mm...
  • Page 29 CUT OUT 1165 Drawn b Material Drawn by: D. Izquierdo GA-1200S Code: Model: Drawn Material: Thickness Weight: Qty. Descrip Materi Model: SCHWEIGEN Observa Model Description: GA-1200S Date: 23/07/2020 Sheet: Descr Rev. Scale: Observations: Obser Model: GA-1200S Feeding Voltage: 220-240V 50Hz Max Lamp Power: 2 x GLED Square 55 x 55mm 2.1W 12V 4000k...
  • Page 30: Disposal Of Old Appliances

    All pictures used in own determination as to its suitability for their the guide are for illustrative purposes only. purpose/s prior to use. In no event will Schweigen Although our information and marketing states Home Appliances be responsible for damages of the term ‘Silent’...
  • Page 31 Page 31...
  • Page 32 © Schweigen Home Appliances Pty Ltd. 2020. Australia 8/3-4 Anzed Court, Mulgrave, Victoria 3170 Phone: 1300 881 693 Email: sales@schweigen.com.au New Zealand 5 Tolich Place, Henderson, Auckland 0610 Phone: 0800 200 510 Email: info.parex@emerson.com www.schweigen.com.au...

This manual is also suitable for:

Ga-1200sKls-9glassblksKls-9glass

Table of Contents