Environmental conditions

Phenomena
Temperature
Humidity
Altitude
Enclosure
Dimension W x H x D
Weight
Degree of protection
Cooling
Mounting
Type tests immunity
Environmental
Phenomena
Electrostatic discharge
Test
RF field AM modulated
Electrical fast transient
Burst
Surge
RF conducted
Power frequency
(50 Hz) magnetic field
Slow damped oscillatory wave
immunity test, 1 MHz burst
Power frequency immunity test
Voltage dips, short interruptions
and voltage variations on d.c.
input power port immunity tests
6
Test
Description
Operating
Storage & Transport
Operating
Storage & Transport
Operating
UL 94
Zink
IEC 529
Enclosure
Basic
Level
Standard
EN 61000-4-2
6kV/8kV (contact/air)
Performance Criteria B
EN 61000-4-3
20V/m 80–2700 MHz
Performance Criteria A
EN 61000-4-4
±4.0 kV (power ports)
±4.0kV (signal ports)
Performance Criteria A
EN 61000-4-5
±4.0 kV (L-E power)
±2.0 kV (L-L power)
±2.0 kV (L-E signal)
±1.0 kV (L-L signal)
Performance Criteria B
EN 61000-4-6
10V/m 0,15 to 80MHz
(power & signal port)
Performance Criteria A
EN 61000-4-8
300 A/m
EN 61000-4-18
2.5 kV (CM)1.0 kV (DM)
IEC 60255-22-7
EN 61000-4-29
Dips:
(DC port)
30 %, 60%
10, 30, 50, 100, 300, 1000 ms
Interruptions:
1, 3, 10, 30, 50, 100, 300, 1000, 5000 ms
Variations:
80%, 120%, 10 s
Performance Criteria A < 50ms
Performance Criteria B > 50ms
Test levels
–20 to +55ºC
–40 to +85C
5 to 95% relative humidity
5 to 95% relative humidity
Up to 2 000 m / 70 kPa
Flammability class V-1
52.5 x 100 x 101 mm
0.6 kg
IP 40
Convection
Horizontal on 35 mm DIN-rail
6621-2260

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pilot wire rpw600f