QUARTZ-COMPACT Software Manual Introduction The QUARTZ-COMPACT Series is a range of UMTS / LTE routers enabling mobile broadband and machine to machine (M2M) industrial communication. This document is aimed at providing guidance when configuring and using the QUARTZ-COMPACT Series router software.
10 years. We supply our products globally to many of the world’s leading organisations. Whether you require an off the shelf or custom solution, Siretta has a wide portfolio of antenna, RF cable assemblies and modems to fit your application.
Software Manual General Description The Siretta QUARTZ-COMPACT router series is a range of high speed industrial cellular routers in a compact enclosure. The QUARTZ-COMPACT series is offered in 3G / WCDMA/UMTS and 4G / LTE forms giving reliable, secure and high speed wireless connectivity.
QUARTZ-COMPACT Software Manual Local Configuration The QUARTZ-COMPACT Series router supports configuration by local Ethernet port, you can specify a static IP or DHCP get IP for your computer. Default IP address: 192.168.1.1 subnet mask: 255.255.255.0 Follow the steps below to configure your router locally: Step 1.
Page 7
Software Manual Step 4. User should use the default user name and password when logging in for the first time. Username: admin Password: admin Figure 2. User identify interface Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com Registered in England No. 08405712 Spencers Wood www.siretta.com...
After visiting the web interface, you can check the current status of the router or modify the router configuration via the web interface. Below is the interface displaying the routers standard settings. Figure 3. Router status GUI Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com...
Input SIM card PIN code if SIM is setup PIN by ISP Cellular mode APN provided by local ISP, usually CDMA/EVDO network do not need this parameter User SIM card username is provided by ISP Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com Registered in England No.
Page 10
3s intervals. If the IP address is still unreachable after the third attempt the router will implement the configured fail action. The Check IP is a public IP or company server IP address. Figure 5. ICMP Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com...
IP address range IP address range within LAN Lease The valid time After all settings have been configured, click the ‘‘Save’’ icon. Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com Registered in England No. 08405712 Spencers Wood www.siretta.com...
Table 3. DDNS settings instruction Parameter Instruction Use default IP 0.0.0.0. For customized protocol, please IP address contact Siretta representative. Auto refresh time Set the interval refresh of the DDNS client to 240s or above Service provider Select the DDNS service provider listed After all settings have been configured, click the ‘‘Save’’...
Interface Interface from router to gateway Description Describe routing name After all settings have been configured, click the ‘‘Save’’ icon. Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com Registered in England No. 08405712 Spencers Wood www.siretta.com...
Int. Address Internal Address. Destination address inside the LAN. Description Remark the rule After all settings have been configured, click the ‘‘Save’’ icon. Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com Registered in England No. 08405712 Spencers Wood www.siretta.com...
IP address. If an IP address is defined, access will be Restriction allowed to this IP address only. Leave Remote Access Leave remote access After all settings have been configured, click the ‘‘Save’’ icon. Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com Registered in England No.
“trigger” is activated Port triggering opens an incoming port when your Note computer is using a specified outgoing port for specific traffic After all settings have been configured, click the ‘‘Save’’ icon. Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com Registered in England No.
The default setting is 1024bytes. Send heart beat to the defined server to keep router Heart-beat Content online. It is convenient to monitor the router from the server. Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com Registered in England No.
Page 19
Parity Bit None as default Data Bit 8bit as default Stop Bit 1bit as default After all settings have been configured, click the ‘‘Save’’ icon. Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com Registered in England No. 08405712 Spencers Wood www.siretta.com...
Step 1. Select “Advanced Network > Upnp/NAT-PMP” to enter the Upnp/NAT-PMP settings. Figure 19. Upnp/NAT-PMP settings After all settings have been configured, click the ‘‘Save’’ icon. NOTE - linkCONNECT and GPS are not available simultaneously on QUARTZ-COMPACT Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com...
Checks the IP address is reachable. If ICMP check is ICMP Check IP Address failed, GRE will be established again. After all settings have been configured, click the ‘‘Save’’ icon. Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com...
Password As the configuration requested Encryption As the configuration requested Stateless MPPE As the configuration requested Accept DNS As the configuration requested Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com Registered in England No. 08405712 Spencers Wood www.siretta.com VAT Registration No.
Page 24
Table 12 (continued). VPN client settings instruction Parameter Instruction Remote Subnet As the configuration requested Create NAT on Tunnel As the configuration requested Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com Registered in England No. 08405712 Spencers Wood www.siretta.com...
Default is empty. Can be customised, maximum 32 characters. Domain Name This is the domain name for the WAN, it will only need to be configured in WAN applications. After all settings have been configured, click the ‘‘Save’’ icon. Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com...
Step 1. Select “Administrator > Time” to enter the time settings. Figure 22. Time settings After all settings have been configured, click the ‘‘Save’’ icon. NOTE - If the device is online but time update fails, try another NTP time server. Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com...
NOTE - The password is the router system account password. Figure 23. Admin settings After all settings have been configured, click the ‘‘Save’’ icon. Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com...
QUARTZ-COMPACT Software Manual SNMP Settings Step 1. Select “Administrator > SNMP” to enter the SNMP settings. Figure 25. SNMP settings After all settings have been configured, click the ‘‘Save’’ icon. Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com Registered in England No.
Step 1. Select “Administrator > Logging” to enter the logging settings. Here you can select the save path for any backed up configurations. (Local or remote server) Figure 31. Log settings After all settings have been configured, click the ‘‘Save’’ icon. Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com...
Step 1. Select “Administrator > Reboot” to reboot the router. A popup will appear, prompting ‘YES’ or ‘NO’ to continue with the reboot. Step 2: If you select ‘YES’, the system will reboot. All relevant firmware upgrades will be effective after the reboot. Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com...
After all settings have been configured, click the ‘‘Save’’ icon. Ping Settings Step 1. Select “Debugging > Ping” to enter the ping settings. Figure 34. Ping settings After all settings have been configured, click the ‘‘Save’’ icon. Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com...
If you want to restore factory settings on your router, this can be done on the web interface by selecting “Administration > Configuration”. Select “Restore Configuration” this will restore your router to it factory settings. Figure 35. Restore configuration Click here to restore factory settings Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com...
LAN IP 192.168.1.1 LAN Subnet Mask 255.255.255.0 DHCP server Enable User Name admin Password admin Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com Registered in England No. 08405712 Spencers Wood www.siretta.com VAT Registration No. GB163 04 0349 Reading...
The max packet for GPS data. After all settings have been configured, click the ‘‘Save’’ icon. NOTE - GPS data format: dtu.heartbeat.content,gps_date, gps_time, gps_use, gps_latitude, gps_NS, gps_ longitude, gps_EW, gps_speed, gps_degrees, gps_FS, gps_HDOP, gps_MSL e.g. Router_00001,083238,120313,12,2230.31563,N,11355.02863,E Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com...
The information contained in this document is proprietary to Siretta. Siretta has made every effort to ensure that the accuracy of the information contained within this document is accurate. Siretta does not make any warranty as to the information contained within this document and does not accept any liability for any injury, loss or damage of any kind incurred by the use of this information.
Need help?
Do you have a question about the QUARTZ-COMPACT Series and is the answer not in the manual?
Questions and answers