• CONTROL PANEL: The control panel (A) located on the top of the appliance has 9 buttons and 6 indicators:
button
: Stand by/start.
A1 Indicator : power on indicator, it lights up as soon as your appliance is switched on.
MODE button : Choice of 4 operating modes:
A2 indicators: Indicators corresponding to the operating mode.
- AUTO: This operating mode allows you to set the desired temperature of the room. The appliance will automatically set
the power level to suit the temperature of your room and the temperature set. A temperature of 21°C is set by default.
-
: Cold ventilation, allows you to use your appliance as an extra fan in summer.
- ECO: Operation at a power of 1200W, automatically set to not exceed 19°C in the room.
- 2400W: Operation at a power of 2400W unregulated (a safety device limits the temperature of the room to 35°C).
Button
: Button used to set the time.
Button
: Function permitting the appliance to be oscillated to optimise the diffusion of air in the room.
Buttons
and
: 2 buttons to set the temperature of the AUTO mode, to set the time and the PROG 24h function.
Button PROG 24h : Function allowing several operating ranges to be set in the day.
Indicator A3: Indicator of the PROG 24h function, it flashes when the function is programmed and lights up when the function is active.
Buttons VALID and ANNUL : 2 buttons used to set the PROG 24h function.
• Display panel:
Your appliance is equipped with a display panel (F), where you can find the following information:
F1- Icons showing the Operating mode chosen (the icon flashes during the regulation
phase in the Temperature AUTO and ECO modes).
F2- Temperatures (in °C):
- When SELECT flashes (in AUTO mode), the temperature displayed is the temperature that you have programmed.
- When "the House" is visible, the temperature displayed is the temperature of the room where the appliance is situated.
F3- Icon visible when the oscillation function is active.
F4- The "PROGRAM" message is visible and flashes only during the PROG 24h function programming.
F5- Clock: this is the clock of the appliance.
- When "PROGRAM" and the clock are visible at the same time (and flash), the time shown is the time
the PROG 24h function is programmed for.
Attention: Check the clock regularly
F6- The "ON" and "OFF" messages are linked to the PROG 24h function programming.
See §3c "PROG 24h: PROGRAMMING".
F7- The bar-graph is linked to the PROG 24h function, it shows the periods of operation in a day
(24 hours with increments of 30 minutes). See §3c "PROG 24h: PROGRAMMING".

OPERATION

Before switching on your appliance check the following:
- The position of the appliance described in these instructions must be respected
- The air inlet and outlet grills must be completely unobstructed
- The appliance must be placed in a horizontal and stable position.
SO7010 MODEL:
1- Connect your appliance, select the desired function, using the C button (fig. 1c), by aligning the mark on the button with the symbol.
2- Set the temperature by turning dial D.
3- You can start oscillation at any time by pressing button E.