Pop nuts tool

Advertisement

3. Stopping the mandrel's counterclockwise rotation.
Release the trigger to stop the mandrel (Figure 6-7).
 
Regular mandrel cleaning and lubricant
-Clean the mandrel after every 50〜60 fastenings. (See Figures 6-8 and 6-9)
After fastening tens of Pop Nuts, metal fragments can stick to the mandrel and
it can run short of lubrication, making it impossible to mount Pop Nuts
smoothly. If you continue to use the tool in this condition, it will become
impossible to mount Pop Nuts at all and the mandrel will wear more rapidly.
4. What to do when the Pop Nut is not detached correctly
(1) If the reverse rotation of the mandrel stops before the Pop Nut is detached from
the mandrel (if you released the trigger too early).
Pull the trigger while pressing the control knob. Mandrel starts reverse rotation
and detaches the Pop Nut (Figure 6-10).
Pull
While pressing
Figure 6-10
 
Trigger
Release
Figure 6-7
Cap screw
Trigger
Control knob
Nose housing
 
 
Figure 6-8
Lock pin holder
Figure 6-11
13
PNT800 
Figure 6-9
Rotate
Figure 6-12