6. How to use the PNT800
Before setting Pop Nuts with this tool, refer to the section "4. Preparations for
use" on pages seven and eight.
《Procedure》
1. Mounting
When the Pop Nut is gripped gently and pressed by the mandrel with a force of
approximately 49N or more, the mandrel turns clockwise.
Screw the Pop Nut down onto the mandrel.
Once the flange of the Pop Nut comes into contact with the nose piece, the
clockwise rotation of the mandrel stops automatically.
Precautions on mounting
Keep pushing until the clockwise rotation of the mandrel stops automatically.
If the Pop Nut is not fully mounted, the caulk stroke will be inconsistent.
Mandrel
Figure 6-1
OK
NG
Figure 6-2
11