Inlet Pressure Gauge; Supply Hose-To-Supply Hose Connections; Supply Hose-To-Attachment Hose Connections - MSA PremAire Cadet Escape G1 Operating Manual

Combination supplied-air respirator with scba for escape
Hide thumbs Also See for PremAire Cadet Escape G1:
Table of Contents

Advertisement

Available languages

Available languages

3.3

Inlet Pressure Gauge

To ensure accurate pressure readings, the inlet pressure gauge must be located at the air source.
3.4

Supply Hose-to-Supply Hose Connections

Use MSA-approved couplings only for supply hose connections.
Hoses must only be interconnected with either the threaded connector (3/4-16 UNF) or locking
quick-disconnect couplings listed below. DO NOT use non-locking quick disconnects to interconnect
air supply hoses.
CEJN - Chrome
SNAP-TITE — Aluminum
SNAP-TITE — Stainless Steel
Locking quick-disconnects connect by pushing the plug and socket together. To separate, push the
plug and socket together, then pull the socket sleeve away from the plug.
3.5

Supply Hose-to-Attachment Hose Connections

Attachment hose connections are to be made through approved MSA couplings only.
CAUTION
PremAire Cadet Escape G1
Operation
US
10