Dimming; Strobe / Shutter; Zoom; Behavior When The Fixture Is Not Receiving A Dmx Signal - GLP Fusion EXO Wash 30 User Manual

Table of Contents

Advertisement

German Light Products®

Dimming

See Figure 6. You can select from two dimming curves using the control panel or the
Control / Settings DMX channel:
● Linear sets dimming so that it appears to increase and decrease evenly throughout
the dimming range.
● Soft gives finer control at low light levels and coarser control at high light levels.
The default setting is Soft.

Strobe / shutter

A variety of strobing and fading effects can be produced by the fixture.

Zoom

The beam angle of the fixture can be adjusted (zoom) from 4° to 54°. The zoom
operation can be inverted using the menu.

Behavior when the fixture is not receiving a DMX signal

You can set the fixture to react in three different ways if no DMX signal is present (if the
fixture is being controlled by DMX but the DMX signal stops, or if you apply power to
the fixture when no DMX signal is present):
● Blackout sets the fixture to black out. This is the default setting.
● Hold sets the fixture to continue obeying the last DMX values it received. If no DMX
signal was being received, the fixture will black out.
● Preset Scene sets the fixture to output a preset scene which you have previously
captured from an incoming DMX state using the Manual Control > Capture Scene
menu option. You can also manually set the control values (or edit the captured
values) using the attribute settings in the Manual Control menu.
All these settings are available via DMX on the Control / Settings channel and in the
fixture's control panel.