Carrier Atmosphera 42EM Series Manual page 48

Ducted fan coil unit
Table of Contents

Advertisement

Character Codification Description
8,9
BJ
BK
BL
BM
CA
CB
CC
CD
CE
CF
CG
CH
CJ
CK
CL
48
Control (continued)
Maestro control
Unit with Maestro controller, 1
on/off type two-way control valve,
a return air sensor and electric
heater control.
Unit with Maestro controller, 1
on/off type two-way control valve
with flexible water pipes and a
return air sensor.
Unit with Maestro controller, 2
on/off type two-way control valves
with flexible water pipes and a
return air sensor.
Unit with Maestro controller, 1
on/off type two-way control valve
with flexible water pipes, a return
air sensor and electric heater
control.
Unit with Maestro controller and 1
on/off type three-way control valve.
Unit with Maestro controller and 2
on/off type three-way control
valves.
Unit with Maestro controller, 1
on/off type three-way control valve
and electric heater control
Unit with Maestro controller and 1
on/off type three-way control valve
with flexible water pipes.
Unit with Maestro controller and 2
on/off type three-way control valves
with flexible water pipes.
Unit with Maestro controller, 1
on/off type three-way control valve
with flexible water pipes and
electric heater control.
Unit with Maestro controller, 1
on/off type three-way control valve
and a return air sensor.
Unit with Maestro controller, 2
on/off type three-way control valves
and a return air sensor.
Unit with Maestro controller, 1
on/off type three-way control valve,
a return air sensor and electric
heater control.
Unit with Maestro controller, 1
on/off type three-way control valve
with flexible water pipes and a
return air sensor.
Unit with Maestro controller, 2
on/off type three-way control valves
with flexible water pipes and a
return air sensor.
Character Codification Description
8,9
CM
DA
DB
DC
DD
EA
EB
EC
ED
TC
TD
VC
VD
Control (continued)
Maestro control
Unit with Maestro controller, 1
on/off type three-way control valve
with flexible water pipes, a return
air sensor, and electric heater
control.
Unit with Maestro controller, 1
on/off type three-way control valve
and a changeover sensor.
Unit with Maestro controller, 1
on/off type three-way control valve
with flexible water pipes and a
changeover sensor.
Unit with Maestro controller, 1
on/off type three-way control valve,
a changeover sensor and a return
air sensor.
Unit with Maestro controller, 1
on/off type three-way control valve
with flexible water pipes, a
changeover sensor and a return air
sensor.
Unit with Maestro controller, 1
on/off type three-way control valve,
a changeover sensor and electric
heater control.
Unit with Maestro controller, 1
on/off type three-way control valve
with flexible water pipes, a
changeover sensor and electric
heater control.
Unit with Maestro controller, 1
on/off type three-way control valve,
a changeover sensor, a return air
sensor and electric heater control.
Unit with Maestro controller, 1
on/off type three-way control valve
with flexible water pipes, a
changeover sensor, a return air
sensor and electric heater control.
Aquasmart control
Unit with Aquasmart control, 2
on/off type 3-way valves, a water
temp. sensor and a return air
sensor.
Unit with Aquasmart control, 2
on/off type 3-way valves with
flexible water pipes, a water temp.
sensor and a return air sensor.
Unit with Aquasmart control, 1
on/off type 3-way valves, a water
temp. sensor and a return air
sensor.
Unit with Aquasmart control, 1
on/off type 3-way valves with
flexible water pipes, a water temp.
sensor and a return air sensor.

Advertisement

Table of Contents
loading