Carrier 42TVAB010 Owner's Manual
Hide thumbs Also See for 42TVAB010:

Advertisement

Available languages

Available languages

ENGLISH
ภาษาไทย
OWNER'S MANUAL
AIR CONDITIONER (SPLIT TYPE)
For general public use
Indoor unit
42TVAB010, 013, 018, 024, 028, 030, 033 Serise
Outdoor unit
38TVAB010, 013, 018, 024, 028, 030, 033
1122350217

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 42TVAB010 and is the answer not in the manual?

Questions and answers

Summary of Contents for Carrier 42TVAB010

  • Page 1 ENGLISH ภาษาไทย OWNER’S MANUAL AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit 42TVAB010, 013, 018, 024, 028, 030, 033 Serise Outdoor unit 38TVAB010, 013, 018, 024, 028, 030, 033 1122350217...
  • Page 2: Precautions For Safety

    PRECAUTIONS FOR SAFETY Read the precautions in this manual carefully before This appliance is filled with R32. operating the unit. ● Keep this manual where the operator can easily find it. ● Read the precautions in this manual carefully before operating the unit. ● This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons. ● The precautions described herein are classified as DANGER, WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail. DANGER ● Do not install, repair, open or remove the cover. It may expose you to dangerous voltages. Ask the dealer or the specialist to do this. ● Turning off the power supply will not prevent potential electric shock. ● The appliance shall be installed in accordance with national wiring regulation. ● Means for disconnection from the supply having a contact separation of at least 3 mm in all poles must be incorporated in the fixed wiring. ● The appliance must be stored in a room without continuously operating ignition sources (for example, open flames, an operating gas appliance or an operating electric heater). ● In order to avoid fire, explosion or injury, do not operate the unit when harmful gases (e.g. flammable or corrosive) are detected near the unit. WARNING ● Do not expose your body directly to cool or warm air for a long time. ● Do not insert your finger or any article into the air inlet/outlet. ● When an abnormality (burning smell, etc.) occurs, stop the air conditioner and disconnect the power supply or turn off the breaker.
  • Page 3 PRECAUTIONS FOR SAFETY ● Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. ● The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater). ● Be aware that refrigerants may not contain an odour. ● Do not pierce or burn as the appliance is pressurized. Do not expose the appliance to heat, flames, sparks, or other sources or ignition. Else, it may explode and cause injury or death. ● Appliance and pipe-work shall be installed, operated and stored in a room with a floor area larger than A How to get A : A = (M / (2.5 x 0.22759 x h M is the refrigerant charge amount in appliance in kg. h is the installation height of the appliance in m: 0.6 m for floor standing/1.8 m for wall mounted/1.0 m for window mounted/2.2 m for ceiling mounted. (For these units recommend installation height 2.5 m.) CAUTION ● Do not wash the unit with water. It may cause an electric shock. ● Do not use this air conditioner for other purposes such as preserving food, breeding animal, etc. ● Do not step or put anything on the indoor/outdoor unit. It may cause an injury or damage the unit. ● Do not touch aluminium fin because it may cause an injury. ● Before cleaning the unit, turn off the main switch or the circuit breaker. ● When the unit won’t be used for a long time, turn off the main switch or the circuit breaker.
  • Page 4 INDOOR UNIT DISPLAY REMOTE CONTROL 1 Wi-Fi access (White) Infrared signal emitter 2 ECO (White) Start/Stop button 3 PURE (White) Mode select button 4 Timer (White) Temperature button 5 Operation mode Fan speed button Menu select button Set louver Up-Down button Set louver Left-Right button Display brightness can be adjusted, follow procedure on 9. Require Wireless LAN connecting adapter which available as accessory. Check button* *Check button under battery cover PREPARATION BEFORE USE Preparing Filters 1. Open the air inlet grille and remove the air filters. 2. Attach the filters. (see detail in the Installation Manual). Loading Batteries (when use wireless operation.) 1. Remove the slide cover. 2. Insert 2 new batteries (AAA type) following the (+) and (–) positions. Remote Control Reset 1. Remove the batteries.
  • Page 5: Menu Setup

    MENU SETUP 8.1 LOUVER SWING and HADA CARE FLOW OPERATION Comfortable air flow can select from feature. For select more setting of Air conditioner such as Louver select Hi Power, OFF Timer and other use MENU button Louver swing opearation: ● To distribute air flow in both vertical and horizontal by swing the louver automatically. HADA care flow operation: ● Air flow upward to the ceiling, provide Indirect air flow to body and homogenize room temperature. Note: ● During HADA CARE FLOW mode, FIX button cannot active. Louver Swing and HADA Care Flow Operation Setting 1. Press MENU button for enter menu selection During triangle mark blink can select menu by press TEMP. button.
  • Page 6: Hi Power Operation

    Hi-P 8.2 SILENT OPERATION (Outdoor Unit) 8.3 Hi POWER OPERATION To automatically control room temperature and airflow for faster cooling Keep outdoor unit operating silently to ensure either yourself or neighborhood operation (except in DRY and FAN ONLY mode) will have a tight sleep in nighttime. By this feature, the cooling capacity will be optimized to deliver such silent experience. The silent operation can be 1. Press MENU button for enter menu setting and press TEMP. button to selected from one of two purposes (Silent 1 and Silent 2). select Hi POWER There are three setting parameters: Standard level > Silent 1 > Silent 2 Silent 1: Blink both triangle and ● Though operating silently, the Cooling capacity is still prioritized to ensure feature mark Feature not having sufficient comfort inside the room. yet set ● This setting is a perfect balance between the Cooling capacity and the Sound level of outdoor unit. 2. Confirm selected feature by press MENU button again. Silent 2: ● Compromising the Cooling capacity to the Sound level in any circumstance where the outdoor unit’s sound level is highly prioritized. Blink only triangle Feature ● This setting has a purpose to reduce the maximum sound level of outdoor already set unit.
  • Page 7 PURE 8.5 TIMER OFF OPERATION 8.6 PLASMA ION OPERATION To set the timer OFF when the air conditioner is operating. Capture efficiency of floating impurities in the air is accelerated by plasma ion contaminates such as bacteria, odor, smoke, dust and virus are caught and 1. Press MENU button for enter menu setting and press TEMP. button to deactivated by Plasma Ion. select TIMER OFF. 1. Press MENU button for enter menu setting and press TEMP. button to select PURE Blink both triangle and feature mark Feature not Blink both triangle and yet set feature mark Feature not yet set 2. Enter TIMER set by press MENU button. 2. Confirm selected feature by press MENU button again. triangle mark will stop blink and setting feature will be blink instead. Blink only triangle Feature already set 3. Leave from menu setting display by select EXIT. 3. Select TIMER OFF by press TEMP. button. Can select TIMER OFF from 0.5 - 12hrs. Note: ● Plasma Ion operation dose not remove harmful substances from cigarette smoke (carbon monoxide etc.). Open a window occasionally for ventilation. 4. Confirm TIMER OFF by press MENU button. 8.7 POWER-SELECTION OPERATION Blink only triangle This function is used when the circuit breaker is shared with other electrical Feature already set...
  • Page 8: Maintenance

    DISPLAY LAMP BRIGHTNESS ADJUSTMENT REMOTE CONTROL A-B SELECTION To decrease the display lamp brightness or turn it off. To separate using of remote control for each indoor unit in case of 2 air conditioners are installed nearly. 1. Press and hold for 3 seconds until brightness level ( Remote Control B Setup. or ) is shown on remote control LCD then release the button. 1. Press RESET button on the indoor unit to turn the air conditioner ON. 2. Point the remote control at the indoor unit. 2. Press or to adjust brightness in 4 levels. Rise 3. Push and hold button on the back side of Remote Control “00” will be Decrease shown on the display. (Picture 1 ) Remote control Operation display Brightness 4. Press during pushing . “B” will show on the display and “00” will disappear and the air conditioner will turn OFF. The Remote Control B is memorized. (Picture 2 ) 100% Note: 1. Repeat above step to reset Remote Control to be A.
  • Page 9 ข้ อ ควรระวั ง เพื ่ อ ความปลอดภั ย โปรดอ่ า นคำ า เตื อ นในคู ่ ม ื อ นี ้ อุ ป กรณ์ น ี ้ เ ติ ม ด้ ว ยสารทำ า ความเย็ น R32 อย่ า งละเอี ย ดก่ อ นการใช้ ง าน •...
  • Page 10 ข้ อ ควรระวั ง เพื ่ อ ความปลอดภั ย • เครื ่ อ งปรั บ อากาศจะต้ อ งได้ ร ั บ การติ ด ตั ้ ง การบำ า รุ ง รั ก ษา และการซ่ อ มแซม และถอดออกโดย ผู ้ ต ิ ด ตั ้ ง หรื อ ผู ้ ใ ห้ บ ริ ก ารที ่ ม ี ค ุ ณ สมบั ต ิ เ หมาะสม เมื ่ อ มี ง านใดๆ ที ่ เ กี ่ ย วข้ อ งกั บ เครื ่ อ งปรั บ อากาศนี ้ ให้...
  • Page 11 รี โ มทคอนโทรล การแสดงผลบนตั ว เครื ่ อ งปรั บ อากาศ การเข้ า ถึ ง (สี ข าว) Wi-Fi ตั ว ส่ ง สั ญ ญาณอิ น ฟราเรด (สี ข าว) ปุ ่ ม เปิ ด -ปิ ด โหมด (สี ข าว) PURE ปุ...
  • Page 12 การตั ้ ง ค่ า เมนู 8.1 โหมดการส่ า ยใบปรั บ ทิ ศ ทางลมและโหมด H.DA สำ า หรั บ เลื อ กการตั ้ ง ค่ า อื ่ น ๆ ของเครื ่ อ งปรั บ อากาศ เช่ น ปรั บ เกล็ ด ช่ อ งลม การตั ้ ง ค่ า โหมด ปรั...
  • Page 13 Hi-P 8.2 โหมดการทำ า งานไร้ เ สี ย ง (ตั ว เครื ่ อ งภายนอก) 8.3 โหมดเย็ น เร็ ว เปิ ด ใช้ โ หมดนี ้ เ พื ่ อ ควบคุ ม อุ ณ หภู ม ิ ห ้ อ งและกระแสลมอั ต โนมั ต ิ เ พื ่ อ ทำ า ให้ ห ้ อ งเย็ น เร็ ว ขึ ้ น โหมดการทำ...
  • Page 14 PURE 8.6 โหมดฟอกอากาศด้ ว ยประจุ พ ลาสม่ า ไอออน 8.5 โหมดการทำ า งานตั ้ ง เวลาปิ ด เพิ ่ ม ประสิ ท ธิ ภ าพการดั ก จั บ สิ ่ ง สกปรกที ่ ป ะปนอยู ่ ใ นอากาศด้ ว ยประจุ พ ลาสม่ า ไอออน ตั ว ประจุ พ ลาสม่ า ตั...
  • Page 15 การเลื อ กรี โ มท โหมด การปรั บ ตั ้ ง ความสว่ า งหลอดไฟแสดงผล ในการลดความสว่ า งของหลอดไฟแสดงผลหรื อ ปิ ด การแสดงผล สำ า หรั บ แยกการใช้ ร ี โ มทคอลโทรลควบคุ ม การทำ า งานเครื ่ อ งปรั บ อากาศแต่ ล ะตั ว ในกรณี ท ี ่ ต ิ ด เครื...
  • Page 20 1122350217...

Table of Contents