Carrier Atmosphera 42EM Series Manual page 45

Ducted fan coil unit
Table of Contents

Advertisement

Character Codification Description
8,9
AD
AE
AF
AG
AH
AJ
AK
AL
AM
AN
AP
AQ
AR
AS
Control (continued)
Terminal strip and plastic cover
Unit with 1 on/off type two-way
control valve, cables wired to a
terminal block and protected by a
cover.
Unit with 2 on/off type two-way
control valves, cables wired to a
terminal block and protected by a
cover.
Unit with 1 on/off type two-way
control valve, electric heater relay,
cables wired to a terminal block
and protected by a cover.
Unit with 1 on/off type two-way
control valve with flexible water
pipes, cables wired to a terminal
block and protected by a cover.
Unit with 2 on/off type two-way
control valves with flexible water
pipes, cables wired to a terminal
block and protected by a cover.
Unit with 1 on/off type two-way
control valve with flexible water
pipe connectors, electric heater
relay, cables wired to a terminal
block and protected by a cover.
Unit with 1 on/off type three-way
control valve, cables wired to a
terminal block and protected by a
cover.
Unit with 2 on/off type three-way
control valves, cables wired to a
terminal block and protected by a
cover.
Unit with 1 on/off type three-way
control valve, electric heater relay
cables wired to a terminal block
and protected by a cover.
Unit with 1 on/off type three-way
control valve with flexible water
pipes, cables wired to a terminal
block and protected by a cover.
Unit with 2 on/off type three-way
control valves with flexible water
pipes, cables wired to a terminal
block and protected by a cover.
Unit with 1 on/off type three-way
control valves with flexible water
pipes, electric heater relay, cables
wired to a terminal block and
protected by a cover.
Unit with 1 on/off type three-way
control valve, changeover switch,
cables wired to a terminal block
and protected by a cover.
Unit with 1 on/off type three-way
control valves with flexible water
pipes, changeover switch, cables
wired to a terminal block and
protected by a cover.
Character Codification Description
8,9
AT
AU
AV
AW
FA
FB
FC
FD
Control (continued)
Terminal strip and plastic cover
Unit with 1 on/off type two-way
control valve, fan and electric
heater cables wired to a terminal
block and protected by a cover
(without electric heater relay).
Unit with 1 on/off type two-way
control valve with flexible water
pipe connectors, fan and electric
heater cables wired to a terminal
block and protected by a cover
(without electric heater relay).
Unit with 1 on/off type three-way
control valve with fan and electric
heater cables wired to a terminal
block and protected by a cover
(without electric heater relay).
Unit with 1 on/off type three-way
control valve with flexible water
pipes with, fan and electric heater
cables wired to a terminal block
and protected by a cover (without
electric heater relay).
Unit with 1 on/off type three-way
control valve, changeover switch
fan and electric heater cables wired
to a terminal block and protected by
a cover (with electric heater relay).
Unit with 1 on/off type three-way
control valve with flexible water
pipes, changeover switch, fan and
electric heater cables wired to a
terminal block and protected by a
cover (with electric heater relay).
Unit with 1 on/off type three-way
controls valve, changeover switch,
fan and electric heater cables wired to
a terminal block and protected by a
cover (without electric heater relay).
Unit with 1 on/off type three-way
control valve with flexible water
pipes, changeover switch, fan and
electric heater cables wired to a
terminal block and protected by a
cover (without electric heater relay).
45

Advertisement

Table of Contents
loading