Character Codification Description
8,9
HC
HD
QD
QE
QF
QG
QH
QJ
QK
QL
QM
46
Control (continued)
Terminal strip and metal cover
Unit without control valves for 2-
pipe or 4-pipe configuration with
fan cables wired to a terminal block
and protected by a metal cover.
Unit without control valves for 2-
pipe 2-wire configuration with fan
and heater cables wired to a terminal
block and protected by a metal cover.
Unit with 1 on/off type two-way
control valve, cables wired to a
terminal block and protected by a
metal cover.
Unit with 2 on/off type two-way
control valves, cables wired to a
terminal block and protected by a
metal cover.
Unit with 1 on/off type two-way
control valve, electric heater relay,
cables wired to a terminal block
and protected by a metal cover.
Unit with 1 on/off type two-way
control valve with flexible water
pipes, cables wired to a terminal
block and protected by a metal
cover.
Unit with 2 on/off type two-way
control valves with flexible water
pipes, cables wired to a terminal
block and protected by a metal
cover.
Unit with 1 on/off type two-way
control valve with flexible water
pipe connectors, electric heater
relay, cables wired to a terminal
block and protected by a metal
cover.
Unit with 1 on/off type three-way
control valve, cables wired to a
terminal block and protected by a
metal cover.
Unit with 2 on/off type three-way
control valves, cables wired to a
terminal block and protected by a
metal cover.
Unit with 1 on/off type three-way
control valve, electric heater relay
cables wired to a terminal block
and protected by a metal cover.
Character Codification Description
8,9
QN
QP
QQ
QR
QS
QT
QU
QV
QW
Control (continued)
Terminal strip and metal cover
Unit with 1 on/off type three-way
control valve with flexible water
pipes, cables wired to a terminal
block and protected by a metal
cover.
Unit with 2 on/off type three-way
control valves with flexible water
pipes, cables wired to a terminal
block and protected by a metal
cover.
Unit with 1 on/off type three-way
control valves with flexible water
pipes, electric heater relay, cables
wired to a terminal block and
protected by a metal cover.
Unit with 1 on/off type three-way
control valve, changeover switch,
cables wired to a terminal block
and protected by a metal cover.
Unit with 1 on/off type three-way
control valves with flexible water
pipes, changeover switch, cables
wired to a terminal block and
protected by a metal cover.
Unit with 1 on/off type two-way
control valve, fan and electric
heater cables wired to a terminal
block and protected by a metal cover
(without electric heater relay).
Unit with 1 on/off type two-way
control valve with flexible water
pipe connectors, fan and electric
heater cables wired to a terminal
block and protected by a metal cover
(without electric heater relay).
Unit with 1 on/off type three-way
control valve with fan and electric
heater cables wired to a terminal
block and protected by a metal cover
(without electric heater relay).
Unit with 1 on/off type three-way
control valve with flexible water
pipes with, fan and electric heater
cables wired to a terminal block
and protected by a metal cover
(without electric heater relay).