Huawei UPS5000-E Series Quick Manual

Huawei UPS5000-E Series Quick Manual

Hide thumbs Also See for UPS5000-E Series:

Advertisement

Quick Links

UPS5000-E-(30 kVA-120 kVA)-FM
Quick Guide
Issue: 02
Part Number: 31500DCY
Date: 2020-11-10
1
Overview
UPS Model
UPS5000-E-120K-FM
1. Before installation, read the user manual carefully to get familiar with product information
and safety precautions.
2. Use insulated tools when installing the equipment.
3. Only engineers certified by Huawei or its agent are allowed to install, commission, and
maintain the UPS. Otherwise, personal injury or equipment damage may occur, and the
resulting UPS faults are beyond the warranty scope of Huawei.
Capacity Configuration
30 kVA, 60 kVA, 90 kVA,
120 kVA
Copyright © Huawei Technologies Co., Ltd. 2020. All rights reserved.
Weight (Full
Configuration)
310 kg
(1) Cover
(2) Output switch
(3) Maintenance bypass switch
(4) Bypass input switch
(5) Mains input switch
(6) Surge protective module
(optional)
(7) Control module
(8) Bypass module
(9) Power modules
(10) Monitor display module (MDU)
(11) Folder
1
Dimensions (H x W
x D)
2000 mm x 600 mm
x 850 mm

Advertisement

Table of Contents
loading

Summary of Contents for Huawei UPS5000-E Series

  • Page 1 2. Use insulated tools when installing the equipment. 3. Only engineers certified by Huawei or its agent are allowed to install, commission, and maintain the UPS. Otherwise, personal injury or equipment damage may occur, and the resulting UPS faults are beyond the warranty scope of Huawei.
  • Page 2: Installing The Ups

    Installing the UPS Secured Installation 1. Determine the position for installing the 2. Use a hammer drill to drill four holes for cabinet. Mark mounting holes based on installing expansion bolts and then install four the drawings. (unit: mm) expansion bolts in the holes. Remove the bolt, spring washer, and flat washer.
  • Page 3: Connecting Cables

    Connecting Cables UPS Cable Connection Reference • Prepare cables away from the cabinets to prevent scraps from falling inside. Cable scraps may ignite and cause personal injury or device damage. • After cables have been installed, clean the cabinets in a timely manner. Keep the cabinets and surrounding environment clean and tidy.
  • Page 4 3. Connect the ground cable, power cable, and signal cable. There is no need to connect the bypass input power cable if the mains input and bypass input share a power source. Signal cable Port Bolt Torque Description Specifications Mains input M10 x 30 26 N•m Bypass input...
  • Page 5 Scenario 2: Routing Cables from the Bottom A cable entry cabinet needs to be installed when cables are routed from the bottom. This document uses the cable entry cabinet installed on the right of the UPS cabinet as an example. 1.
  • Page 6 9. Remove covers from the top of the cable 10.Remove a certain number of small covers entry cabinet based on the site requirements. from the bottom of the cable entry cabinet based on the actual cable conditions. 11.Connect ground cables and power cables. For the screw specifications and torque used for connecting cables in a bottom cable routing scenario, refer to the top cable...
  • Page 7: Verifying The Installation

    12.Remove the signal cable trough cover 13.Connect the signal cable. (Route the signal from the cable entry cabinet. cable out of the UPS cabinet through the cable hole on the top, and then into the cable entry cabinet through the cable hole on the top of that cabinet.) If the cable entry cabinet is placed on the left of the...
  • Page 8: Powering On And Starting The Ups

    (Optional) If a surge protective module is configured, turn on its switch. Close the UPS bypass input switch, output switch, and mains input switch. After the UPS is powered on, initialization begins. The MDU displays the Huawei logo and an initialization progress bar.
  • Page 9: Initial Startup

    Initial Startup • If the UPS is powered on for the first time, you need to obtain the startup password from the Service Expert app. Skip this step if the UPS is not powered on for the first time. • The Service Expert app can be downloaded from Google Play Store and can run on Android. 1.
  • Page 10 2. Set the language, time, date, network parameters, and system parameters on the Settings Wizard screen. 3. After you perform the settings, the Bypass mode and No battery alarms are reported by the MDU and do not need to be cleared. If there is any other alarm, you need to rectify the fault.
  • Page 11: Shutting Down The Ups

    Powering On Loads 1. After the inverter starts, the UPS works in normal mode. The Bypass mode alarm disappears from the MDU. 2. After confirming that the battery strings are properly connected, turn on the battery string input circuit breaker. If there are multiple battery strings, turn on the circuit breaker for each battery string and then turn on the general circuit breaker between battery strings and the UPS.
  • Page 12 Scan here for technical support (carrier): Huawei App Store Scan here for more documents: Support-E Support WeChat You can also log in to Huawei technical support website: https://support.huawei.com/enterprise https://support.huawei.com Huawei Technologies Co., Ltd. Huawei Industrial Base, Bantian, Longgang Shenzhen 518129 People's Republic of China...

This manual is also suitable for:

Ups5000-e-120k-fm

Table of Contents