Ethernet Cabel Overview For Interconnection - Pepperl+Fuchs EI-0D2-10Y-10B Manual

Ethernet isolator
Table of Contents

Advertisement

ETHERNET ISOLATOR
Installation and Commissioning
Ethernet Wiring
1.
Plug in the standard, non-specific Ethernet cable into the non-I.S.-ports of the device.
2.
Now interconnect the two Ethernet Isolators by plugging in an Ethernet cable into both I.S.-
ports of the devices.
3.2.1

Ethernet Cabel Overview for Interconnection

The cross-table below gives a general idea which Ethernet cable has to be used for
interconnection of two Ethernet Isolators or an Ethernet Isolator to another device.
Ethernet Isolator I.S.-port
Switched standard-port
Switch uplink-port
Notebook
Workstation
Device with auto-crossover
functionality
General Information about Standard Ethernet Patch and Crossover Cables
The TIA/EIA-568-B Ethernet connector specification defines two types of pin assignment for an
Ethernet cable. The standard Ethernet patch cable is a straight through connection of where
both RJ45 ends wired the same. The Ethernet crossover cable has the RX and TX pairs
switched between the end terminals.
Ethernet
I.S. Port
Isolator
ACT
10BASE-T/
100BASE-TX
PWR
10/100
®
ACT
Non-I.S. Port
Ethernet Isolator I.S.-port
Crossover cable
not allowed
not allowed
not allowed
not allowed
not allowed
Ethernet
I.S. Port
Isolator
ACT
10BASE-T/
100BASE-TX
PWR
10/100
®
ACT
Non-I.S. Port
Ethernet Isolator non-I.S.-
port
not allowed
Crossover cable
Standard patch cable
Standard patch cable
Standard patch cable
Standard patch cable