Operating mode "Piston Pump" for pulsating flows.
In this operating mode an improved reproducibility is achieved in
the flow signal measurements for pulsating flows in piston pump
applications.
In order to realize a quiet instantaneous flow indication and a
smooth current output a special software filter can be activated in
the converter. The filter should be turned "on" for piston pump
operation. The damping time should be selected greater than
2.4 s, otherwise the software filter will not be operational.
Selection of the flow direction
Forward/reverse or forward only
If the flow is in the reverse direction when forward only is
selected, the flow direction indicator
and the flowrate is set to 0 %.
Normal/Inverse
Reverse the forward/reverse flow direction indicators.
See display.
When a converter is exchanged the meter location
parameters can be uploaded into the replacement
converter.
After the start-up configuration has been completed or after
instrument settings have been changed, the new or revised
parameter settings can be stored in the external EEPROM.
Software version
In the 1st line the instrument designation is displayed together
with the revision date of the software 01/00. In the 2nd line the
software designation (D699B154U01, for HART D699B164U01)
and the software version are displayed.
An alphanumeric meter identification TAG-Number, with up to 16
characters, can be entered utilizing lower and upper case letters
and numbers.
Only for ABB Fischer & Porter Service.