Accessory Connections; Ul, Re-Open (Monitored Input Terminals) - Viking Access Systems I-770 Installation Instructions And Safety Information

Single and dual gate systems
Table of Contents

Advertisement

UL
(Monitored Input Terminal)
The "UL" input terminal
entrapment in both the opening and
closing directions. Input will reverse
the gate momentarily in the opposite
direction it was traveling
connected device it triggered. see pages
10-11.
Check for proper operation:
When a connected device is triggered, the
"UL" LED will illuminate and, if more than
one Monitored device connected, the "Stop"
LED will flash rapidly to indicate an input.
!
If more than one Monitored device is
connected to this terminal, the "UL" LED will
be illuminated. This alone is inconsequential.
!
TECHNICAL TIP:
For more information regarding accessory connections to the control board
and individual input terminal functions, refer to "Appendix (A)" pages 42-43.
VIKING TECHNICAL SUPPORT 1.800.908.0884

ACCESSORY CONNECTIONS

protects against
when a
NOTE:
will be flashing if there
is a failure with at
least one monitored
entrapment sensor and
the gate operator will
be rendered inoperable.
Re-Open
(Monitored Input Terminal)
The "Re-Open" input terminal
against entrapment in the closing
direction ONLY. Input will reverse the
gate all the way to the Open Limit
a connected device it triggered. see pages
10-11.
The "Stop" LED
Check for proper operation:
When a connected device is triggered, the "Re-
Open" LED will illuminate and, if more than one
Monitored device connected, the "Stop" LED will
flash rapidly to indicate an input.
!
If more than one Monitored device is
connected to this terminal, the "Re-Open" LED
will be illuminated. This alone is inconsequential.
protects
when
2 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents