Safety communications
This function allows safety data to be exchanged between safety stations on the same network.
Function
Safety communications
Troubleshooting
This function checks the status of modules and networks by executing diagnostics and operation tests using the engineering
tool.
Function
Module communication test
CC-Link IE TSN/CC-Link IE Field
diagnostics
Communication test
Others
Function
"CC-Link IE TSN
Parameter setting of a
Configuration"
slave station
window
Detection of
connected/
disconnected devices
Parameter processing
of a slave station
Command execution
to slave stations
Reserved station setting
Error invalid station setting
Slave station parameter automatic setting
Station number setting using a program
Data collection using CC-Link IE TSN
Communication Software
3 FUNCTION LIST
22
Description
Establishes a safety connection and enables one-on-one safety
communications periodically between safety stations in the same network.
Description
Checks the module hardware when the communication using the
RJ71GN11-T2 is unstable.
Monitors the status of CC-Link IE TSN. The network maps, stations where
data link is not operating, selected station communications status monitor
and so on are displayed on the engineering tool.
Checks if transient transmission data can be properly routed from the own
station to the communication target.
Description
Sets parameters of slave stations (the number of points and assignment of
link devices) in the master station.
Detects connected slave stations and the stations are displayed on the "CC-
Link IE TSN Configuration" window.
Reads and saves the parameters from the slave station, and writes the
saved parameters to the slave station.
Executes commands (Error clear request, Error history clear request) to a
slave station.
A slave station that is set in the parameters and included as a station in the
network when its number is counted. This station reserved for network
extension in the future, and thus the station is not actually connected, and is
not detected as a faulty station despite being not connected.
A slave station that is set to be not detected as a faulty station by the master
station.
Saves parameters of the slave station to the master station, and sets the
parameters automatically when the slave station is connected or returned to
the network.
Sets a station number and IP address using a program to the own station
with no station number and IP address setting. This function allows project
data items of stations with the same program and network parameters
(excluding the station numbers and IP addresses) to be the same, leading to
reduced development work hours. ( MELSEC iQ-R Programming Manual
(Module Dedicated Instructions))
Receives cyclic data on CC-Link IE TSN using CC-Link IE TSN
Communication Software.
For details on CC-Link IE TSN Communication Software, refer to the
following.
 CC-Link IE TSN Communication Software for Windows User's Manual
Availability
Master
Local
station
station
Availability
Master
Local
station
station
Availability
Master
Local
station
station