Politec ALES 60 Quick Start Manual

Politec ALES 60 Quick Start Manual

Infrared perimetral barrier double beams
Hide thumbs Also See for ALES 60:

Advertisement

Quick Links

INFRARED PERIMETRAL BARRIER
DOUBLE BEAMS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALES 60 and is the answer not in the manual?

Questions and answers

Summary of Contents for Politec ALES 60

  • Page 1 INFRARED PERIMETRAL BARRIER DOUBLE BEAMS...
  • Page 2  Do not install multiple beams where the transmitter beam can interfere with other receiver beams. It is always better place either transmitter or receivers back to back. Politec S.r.l. | Manual Ales – Ver. 1.7.2...
  • Page 3 1. MAIN COMPONENT LIST Terminal Block Channel selector TEST button Tamper Switch Horizontal adjustment screw Adjustment Buzzer (RX) Adjustment high frequency led (RX) Vertical adjustment screw Lens 10 Unit base Politec S.r.l. | Manual Ales – Ver. 1.7.2...
  • Page 4: Mounting Plate

    COVER MOUNTING PLATE “U” BRACKET FOR POLE MOUNTING Politec S.r.l. | Manual Ales – Ver. 1.7.2...
  • Page 5: Installation Tips

    In case of repairs covered by warranty (2 years) but with obvious signs of improper installation, the Politec s.r.l. reserves the right to decide on any repair costs.
  • Page 6: Pole Mounting

    1,5 mm² 490 m 2,5 mm² 820 m BODY METAL SUPPLY LAR22 IS NOT WATERPROOF AND WILL NOT BE PLACE OUTSIDE THE PREMISES WITHOUT BEING PLACED IN TURN INSIDE A SEALED CONTAINER Politec S.r.l. | Manual Ales – Ver. 1.7.2...
  • Page 7: Transmitter / Receiver

    TX must be corresponding to that of the RX Tamper input additional, in case of absence MUST remain closed by 6 TMP 1 jumper 7 TMP Tamper anti cover removal Politec S.r.l. | Manual Ales – Ver. 1.7.2...
  • Page 8: Frequency Selection

    1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Politec S.r.l. | Manual Ales – Ver. 1.7.2...
  • Page 9 Press the TEST button on the RX mother board for 3 seconds until the buzzer will beep twice, accompanied by two blinking of LEDs, to begin calibration. Press the TEST button on the RX Column Power on of buzzer and LEDs on RX column Politec S.r.l. | Manual Ales – Ver. 1.7.2...
  • Page 10 TEST button for 3 seconds on RX mother board. Two beeps of buzzer will indicate the end of the TEST function. ► After adjusting for the next 3 minutes each alarm event will be highlighted by a beeper Politec S.r.l. | Manual Ales – Ver. 1.7.2...
  • Page 11: Setting Time

    500 ms. And 'possible to obtain the means of intervention 750ms taking further down the TEST button until the fourth consecutive BEEP.  To reset the time back to the first point of intervention. Politec S.r.l. | Manual Ales – Ver. 1.7.2...
  • Page 12 Politec S.r.l. | Manual Ales – Ver. 1.7.2...
  • Page 13 On mother boards TX and RX there is a supplementary Tamper input useful to add a wall tamper. In case of absence of additional Tamper, Check the closing of the contact by a jumper. Tamper input additional, in case of absence MUST be closed by jumpers. Politec S.r.l. | Manual Ales – Ver. 1.7.2...
  • Page 14: Technical Features

    10/15V = 6W, 0.4 A cad. 20/30V = 6W, 0.2 A cad. Tamper output contact NC Operating temperature -25° (with Heather) +65° IP protection IP65 Mounting brackets for wall/pole TOTAL WARRANTY 2 YEARS Politec S.r.l. | Manual Ales – Ver. 1.7.2...
  • Page 15 For long range protection is suggested the use of thermostat warranting an enough supply to it. Politec S.r.l. | Manual Ales – Ver. 1.7.2...
  • Page 16 If a switching power supply is used, substitute it with a “linear” one to reject any kind of electrical power disturb from line; o If possible, increase the alarm delay up; Politec S.r.l. | Manual Ales – Ver. 1.7.2...

This manual is also suitable for:

Ales 120