Double optic perimeter barrier invisible anti-intrusion system (28 pages)
Summary of Contents for Politec MANA MW
Page 1
Microwave barrier for perimeter protection at long range. Installation manual...
Page 2
TRASMITTER/RECEIVER Pag. 8 FREQUENCY SELECTION Pag. 9 ALLIGNMENT TEST Pag. 9 SETTING TIME Pag. 11 TIME CHOICE Pag. 11 ENVIRONMENTAL DISQUALIFICATION Pag. 13 ADDITIONAL TAMPER Pag. 13 TECHNICAL FEATURES Pag. 14 POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 3
PRINCIPAL COMPINENT Quantity Description Parts Top Cap Aluminium Profile Aluminium inserts IR cover Parable Mana Illuminator Mana Cavity Tx or Rx Handling system Plate Tx or Rx board Power board POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 4
1. ASSEMBLING THE CABLEPIT Insert the highlighted edge into other section and fix with screws Insert the third section in the same way and fix with screws. POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 5
Enlarge the two opposite walls of cable pit to allow the positioning of last section. Insert and well fix the missing screws. POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 6
On the side that must be corrected loosen the insert in order to get the right inclination. CORRECT POSITIONING WRONG POSITIONING BY ADJUSTING INSERTS EXAMPLE OF SETTING POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 7
The following pictures show some typical cases for which the most correct solution is given. POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 8
Along the section, within the area of the protectiion field, are allowed pipes, poles or similiar as long as their dimensions, with respect to the protection beam, are not too excessive. The trees, hedges, bushes in general, need very great attention if near or within the protection sections. POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Led VDC, when the cavity "TX" is inserted. The "channel selector" allows you to select the desired channel by DIP SWITCH switching to "ON". NB The selected channel must be the same as that of the Circuit "Rx”. POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 10
1.1. Connections TX TO CAVITY TX 24.5 GHz POWER INFRARED CONTACT BARRIER TAMPER NC POWER SUPPLIER TO OTHER HEATERS BATTERY 12V TRANSFORMER LAND 230V~ LAND POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 11
(when there is the alarm LED goes LED ALARM off). Red: weak signal LED ALIGNMENT POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 12
Display Value Sensitivity (0 to 9) SENS Display 0.2 ± 5V supply Display 0.2 ± 9V supply Display 13.8 ± 0.3 supply Input Voltmeter (to display items 5 ÷ 9) VOLT POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 13
TO CAVITY TX 24.5 GHz TO CAVITY TX 24.5 GHz POWER INFRARED BARRIER CONTACT CONTACT ALARM NC TAMPER NC POWER SUPPLIER TO OTHER HEATERS HEATER BATTERY 12V TRANSFORMER LAND 230V~ LAND POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 15
The switch located on the cavity Tx and Rx is positioned to OFF only after installation and after giving voltage to the columns. The ON position, the active protection of the "receiver" cavity by electrostatic discharge and damage resulting from installation. POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 16
Within each column is provided space to house a rechargeable Lead 12 V - 1.9 Ah. The internal battery is normally recharged from food through a current limiter. The casings of the battery used, shall have a flammability class HB or better (UL 94) POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 17
The High Risk Protection is essential that the detectors are tested with adequate intervals to Test Operational. In this way the control unit will be able to detect attempts to circumvent. POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 18
Length is in meters : remember to adjust the sensitivity of "MANA" according to half width of the beams is desired. As the threshold is higher, the lower the sensitivity and vice versa. POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 19
70 cm from the center of the antenna to the ground, with the sensitivity set to medium. H equipment ground (cm) Maximum sensitivity Minimum sensitivity Length of the dead zone in meters POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Vertical orientation: Loosen the screws of the handling system of the parable, and rotate. Verify that on the board RX the leds alarm and Channel are on. Otherwise proceed with the electronic alignment, however, be made to obtain a precise alignment. POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 21
The sensitive area is represented by the graph on page 17. 5. Test of the acrossing, making sure the intermittent sound of the buzzer and then the long beep and shutdown "LED Alarm" column on the Rx. BUZZER: NESSUN SEGNALE POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 22
Calibration is performed taking into account the user requirements. Example: the system should not go into alarm when it is crossed by an animal of a certain size. Keep in mind that high sensitivity can generate false alarms. POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Page 23
The potentiometer adjustment of the delay (see page. 11, 12) affect the crossing speed. To verify the delay is necessary to experiment crossing at reduced speed. Remember that setting too high or low could cause false alarms POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Width 25 cm Deepness 20 cm 300 cm WEIGHT From 10 to 20 kg for barrier ALIGNMENT Eletronic with instruments on motherboard OUTPUTS Alarm relay and Tamper ASSISTENZA TECNICA: +39 039 9081616 POLITEC S.r.l. | Manual MANA MW – Ver. 2.2.2...
Need help?
Do you have a question about the MANA MW and is the answer not in the manual?
Questions and answers