2 General data
Capacity tables
2.1 Capacity tables
2.1.1 Nominal capacity-performance tables
2.1.1.1 Considerations
•
The heating capacity tables show the capacity and performance data in integrated values (with defrost correction
factor included).
•
The nominal heating and cooling capacities are based on the EN 14511 standard: Piping length: 7.5 meters; Piping
lift: 0 meters.
Keywords:
•
CAP: Nominal capacity (kW)
•
COP: Coefficient of performance
•
EER: Energy efficiency ratio
•
DB: Dry bulb; WB: Wet bulb (ºC)
•
OAT: Outdoor ambient temperature (ºC)
•
WIT: Water inlet temperature (ºC)
•
WOT: Water outlet temperature (ºC)
2.1.1.2 Capacity-performance data
YUTAKI S
HP
Outdoor unit model
Indoor unit model
OAT
WIT / WOT
(DB/WB)
CAP
(Min./Nom./Max.)
30 / 35 ºC
COP (Nom.)
7 / 6 ºC
CAP (Nom./Max.)
47 / 55 ºC
COP (Nom.)
CAP (Nom./Max.)
30 / 35 ºC
COP (Nom.)
-7 / -8 ºC
CAP (Nom./Max.)
47 / 55 ºC
COP (Nom.)
OAT
WIT / WOT
(DB/WB)
CAP (Nom/Max)
12 / 7 ºC
EER (Nom.)
35 / -- ºC
CAP (Nom/Max)
23 / 18 ºC
EER (Nom.)
17
TCGB0123 rev.2 - 10/2019
2.0 HP
RAS-2WHVRP
RWM-2.0NRE(-W)
-
Unit
kW
1.85 / 4.30 / 6.50
-
5.25
kW
4.30 / 6.00
-
3.00
kW
4.50 / 5.30
-
kW
4.00 / 4.20
-
2.00
-
Unit
kW
4.00 / 5.00
-
4.00
kW
5.50 / 6.40
-
5.40
2.5 HP
RAS-2.5WHVRP
RWM-2.5NRE(-W)
Heating operation
1.85 / 6.00 / 8.60
4.80
6.00 / 7.50
2.85
5.30 / 6.20
2.8
2.70
4.70 / 5.00
1.80
Cooling operation
(Using cooling kit accessory)
5.30 / 6.00
3.60
6.30 / 7.70
5.30
2
3.0 HP
RAS-3WHVRP
RWM-3.0NRE(-W)
2.1 / 8.00 / 11.0
4.60
8.00 / 9.50
2.80
5.80 / 7.50
2.70
5.00 / 5.50
1.75
6.50 / 7.00
3.35
7.00 / 9.00
5.00