Toshiba RAV-GM1601ATP-E (TR) Service Manual page 84

Outdoor unit digital inverter
Hide thumbs Also See for RAV-GM1601ATP-E (TR):
Table of Contents

Advertisement

3. . Outdoor application operati
Optional connector kit (TCB-PCOS1E2)
(1) Peak-cut control
• Saves the power of the outdoor unit by the external peak-cut signal to suppress temporary peak power
dissipation.
• The power saving can be switched to three levels: 75%, 50%, and operation stop.
(2) Night operation
• Reduces the capacity of the air conditioner by the input signal from a commercially available timer
(procured locally) regardless of the outside air temperature or load to reduce operating noise.
(3) Compressor output
• Turns on the no-voltage contact output while the compressor is operating.
- 84 -